3-201 SERIAL FUNCTION F01 - TIME ZONE ENTRY/REQUEST
Use Serial Function F01 to select or determine the time zone offset. NOTE: Function 01 will provide
time zone offset only when the XL-DC is in LOCAL or STANDARD time mode (refer to Function 69).
To request the offset, send F01<CR> to the Serial Port. The port will respond with the following
character string:
F01<SEP><SIGN><HH>:<MM><LT>
where:
F
=
ASCII character F
01
= function
number
<SEP>
=
one or more separator characters: either space, comma or tab.
<SIGN>
=
either no character or + for positive offsets or - for negative
offsets
<HH>
=
one - or two-digit hours offset from +12 to -12 hours
:
=
ASCII character for a colon
<MM>
= two-digit
minutes
offset
<LT>
=
line terminator, either a carriage return and line feed for output strings or
a carriage return only for input strings
Sample request:
F01<CR>
Response:
-4:30<CR><LF>
To set the time zone offset, send a character string with the following format:
Sample entry:
F01 -8:00<CR>
Response:
OK<CR><LF>
Sample request:
F01<CR>
Response:
-8:00<CR><LF>
3-202 SERIAL FUNCTION F02 - 12/24 HOUR FORMAT ENTRY/REQUEST
Use Serial Function F02 to request or set the time display format. To determine the format, send
F02<CR> to the Serial Port. The port will respond with the following character string:
F02<SEP><HH><LT>
where:
F
=
ASCII character F
02
= function
number
<SEP>
=
one or more separator characters: either space, comma or tab
<HH>
=
12 or 24
<LT>
=
line terminator, either a carriage return and line feed for output strings or
a carriage return only for input strings