Sample Entry:
FDDD/HH:MM:SS.mmmQ<CR>
Response:
<SOH>360/22:01:25.602*<CR><LF>
Sample Entry:
FXXX hh,mm,ss XXXX<CR>
Response:
<SOH> 22,01,25 <CR><LF>
Sample Entry:
FDDDAXXT<CR>
Response:
<SOH>360A:01:25.602*<CR><LF>
3-116.4 MODE R - RESET TO DEFAULT AND MODE C
Use Mode R to reset to the default format and return to Mode C. Send the command character R to the
Serial Port and the port will respond by outputting time in the default format once per second. Any
previous Mode F format is canceled.
The data and carriage return timing of the initial output string sent immediately following the command
character R is not reliable. This inconsistency is due to internal synchronization with the data rate.
3-116.5 MODE T - TIME ON REQUEST
Use Mode T to request a single output of time to the nearest millisecond. Send the command character
T to the Serial Port. The unit will save the time of year as of 9 bits after the center of the start bit of the
character T, then the port will immediately respond with a single time data string in the current format
selected. The Serial Port outputs no further data until it receives another command character. The
format of the Mode T string may be altered using Mode F. The default format is:
<SOH>DDD:HH:MM:SS.mmmQ<CR><LF>
where:
<SOH>
=
ASCII start-of-header character (HEX 01).
DDD
=
three-digit day of year.
:
= ASCII
colon
character.
HH
= two-digit
hours.
MM
= two-digit
minutes.
SS
= two-digit
seconds.
.
=
ASCII period character.
mmm
=
three characters for milliseconds.
Q
=
time quality character as described below.
<CR>
=
ASCII carriage return character.
<LF>
=
ASCII line feed character.
The time quality character may be a:
SPACE
which indicates a worst-case error less than threshold 1.
.
which indicates a worst-case error greater than or equal to threshold 1.
*
which indicates a worst-case error greater than or equal to threshold 2.
#
which indicates a worst-case error greater than or equal to threshold 3.
?
which indicates a worst-case error greater than or equal to threshold 4.