10
Maintenance
REPLACING ACTUATORS:
If one actuator needs to be replaced, it is recommended to replace the other — even if it
is not leaking.
1. Confirm that the ToteTilter is in the 0° tilt position, then disconnect the inbound airline at
the pressure regulator.
2. Remove the pneumatic fitting from the actuator, and confirm that it can be reused.
3. Loosen and remove retaining bolts. Once the retaining bolts are free, remove the actuator.
Note
: Keep the retaining bolts — as the new actuators are not shipped with this hardware.
•
3/8” 16 UNC thread
•
Actuator bolt hole depth is 5/8”
4. Place the new actuator where the previous actuator was located.
5. Install and tighten using the retaining bolts from step 3.
•
3/8” 16 UNC thread
•
Actuator bolt hole depth is 5/8”
•
Tightening torque on the blind nut is 15-20 ft.-lbs (See Fig. 1)
6. Install the pneumatic fitting on the new actuator.
•
Use a small amount of Teflon or similar sealing tape on threads.
•
Use caution to avoid cross-threading the pneumatic fitting.
7. Connect the airline to the pneumatic fitting on the newly installed actuator.
Fig. 5 - Cutaway of actuator
To Air Supply
Customer supplies
mounting plates,
bolts, and washers
5/8”
Flexible Actuator Bellows
5/8”