background image

 

        

 

Assembly Instructions

 

IMPORTANT SAFETY INSTRUCTIONS 

 

 

 
Basic Guidelines for Setting Up Your Treadmill 

After removing the treadmill from the packaging, place your treadmill on a clean, level surface. Make 
sure the electrical cord easily reaches a grounded three-pronged outlet and has enough slack to allow 
the deck to incline without tightening the cord. Do not allow the treadmill assembly to rest on the cord. 

 
Important Electrical Requirements 

– 120V 

Your TRUE treadmill requires a dedicated 120 volt, alternating current (AC), 20 amp grounded outlet 
circuit. This means nothing else can be plugged into the same circuit. Most power circuits are rated for 
this 120V AC 20 amp requirement, but you must ensure the treadmill does not share the circuit with 
anything else. 
 

Important Electrical Requirements 

– 220V 

Your TRUE treadmill requires a dedicated 220 volt, alternating current (AC), 10 amp grounded outlet 
circuit. This means nothing else can be plugged into the same circuit. Most power circuits are rated for 
this 220V AC 10 amp requirement, but you must ensure the treadmill does not share the circuit with 
anything else. 
 

Danger: Do not use an extension cord or ungrounded outlet. 

The ground helps prevent electrical damage to your treadmill and enhances your safety by helping to 
prevent shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the 
treadmill is properly grounded. Do not modify the plug provided with the treadmill if it will not fit the 
outlet. Have a proper outlet installed by a qualified electrician. 

 

 

 
Should you need technical assistance in assembly of your Mobility Research Fitness 
product, contact Mobility Research Technical Support at 1-800-332-9255 (USA) or 

[email protected]

 

 

 

 

Read and understand all instructions and warnings prior to use. 

  Obtain a medical exam before beginning any exercise program. If at any time 

during exercise you feel faint, dizzy, or experience pain, stop, consult a physician. 

  Obtain proper instruction prior to use. 

  This treadmill is intended for light commercial use only. 

  Inspect the treadmill for incorrect, worn, or loose components and do not use until 

corrected, replaced, or tightened prior to use. 

  Do not wear loose or dangling clothing while using the treadmill. 

  Care should be used when mounting or dismounting the treadmill. 

  Read, understand, and test the emergency stop procedures before use. 

  Disconnect all power before servicing the treadmill. 

  Do not exceed maximum user weight of 350 lbs. 

  Keep the top side of the moving surface clean and dry. 

  Keep children and animals away. 

  Use caution when moving and assembling treadmill. 

  All exercise equipment is potentially hazardous. If attention is not paid to the 

conditions of equipment usage, death, or serious injury could occur. 

Summary of Contents for GK2200T

Page 1: ...Assembly Instructions GK2200T TREADMILL ASSEMBLY INSTRUCTIONS Frame Assembly 120V 220V ...

Page 2: ...ent shock Check with a qualified electrician or serviceman if you are in doubt as to whether the treadmill is properly grounded Do not modify the plug provided with the treadmill if it will not fit the outlet Have a proper outlet installed by a qualified electrician Should you need technical assistance in assembly of your Mobility Research Fitness product contact Mobility Research Technical Suppor...

Page 3: ...ON QTY A Cup Holder 1 B Frame 1 C Left Upright 1 D Right Upright 1 E Left Handrail 1 F Right Handrail 1 G Upper Shoulder Cover Left 1 H Upper Shoulder Cover Right 1 I Lower Shoulder Cover Left 1 J Lower Shoulder Cover Right 1 L Handrail cover left 2 M Handrail cover right 2 ...

Page 4: ... d Inner Toothed Washer M8 20 e Truss Hex Screw M8xP1 25x80 Blue Nylon patch 4 f Truss Hex Screw M8xP1 25x40 Blue Nylon patch 8 g Cup Holder Fixing Plate 8 h Bottled Silicon DC 100 30C C 1 i T shaped Wrench 8mmx200mm 1 j Open Spanner 17mmx110mmx2 0t 1 k Hex Wrench 5mmx35mmx160mm 1 l Round head Philips Screw M4xP0 7x35 2 m Nylon nut M4 P0 7 2 n POP Pin 1 ...

Page 5: ... included o 2 Phillips Screwdriver not included FRAME ASSEMBLY PROCEDURE CAUTION Use caution when assembling treadmill Unpacking and assembling of this treadmill is a two person task NOTE Remove treadmill components from packaging 1 REMOVE MOTOR COVER a Remove two screws and two Motor Decoration Covers from Frame b Remove seven screws and Motor Cover from Frame Fig 1 ...

Page 6: ...installed b Install Pedestal R D into pedestal support on Frame B while pulling the cable out of pedestal support as shown in Fig 2 1 NOTE Be careful not to pinch cables c Install Pedestal L C into pedestal support on Frame d Using 5mm Hex Key install but do not tighten eight Bolts M8 x 75mm b and Washers M8 as shown in Fig 2 1 Fig 2 ...

Page 7: ...hematic and Frame Cable Routing Diagram at the end of these Assembly Instructions You may remove from packet to aid in assembly but if you remove we recommend you retain these diagrams with the instructions for future reference Step 3 1 CNTRL Control Cable i Route CNTRL Cable KDCA 2B XL 1063B from pedestal towards small circuit board as shown in Step 3 c picture on page 7 and in Fig 3 1 ii Plug CN...

Page 8: ...es Once all eight bolts are installed then tighten all bolts You may need to align Pedestal and Console Rack to install first bolt on both sides c Tighten eight Bolts M8 x 75mm b that secure Pedestals to Frame See Fig 2 d Using the 17mm wrench tighten two Hex Head Bolts until secure against Pedestal legs Then tighten two nuts to secure Hex Head Bolts See Fig 4 1 e Place Motor Cover onto frame Usin...

Page 9: ...Assembly Instructions 8 Fig 4 PEDESTAL TUBING CRADLE Hex Screw Hex Nut ...

Page 10: ... made from Pedestal Right to Console Rack NOTE All three connections made for any Console model b CNTRL Control Cable i Connect CNTRL Cable p n KDCA 2B XL 1063B from Pedestal R to CNTRL Cable p n KDCA 1 XL 1053A from Console Rack See Fig 5 1 NOTE 10 pin connector is polarized Insert properly Fig 5 ...

Page 11: ...Assembly Instructions 10 6 HANDRAIL INSTALLATION a Insert Handrails E F onto Pedestals and secure with four Bolts M8 x 80mm e and Internal Tooth Washer M8 d using 5 mm Hex Key Fig 6 ...

Page 12: ...R COVER TOP INSTALLATION a Using a Phillips screwdriver install Shoulder Cover Top pieces Left G and Right H with three Screws M4 x 10mm c on each side as shown in Fig 7 CAUTION Make sure cabling is NOT pinched during installation Fig 7 ...

Page 13: ...ALLATION a Using a Phillips screwdriver magnetic tip option can be used install Shoulder Cover Bottom pieces Left G and Right H with five Screws M4 x 10mm c on each side as shown in Fig 8 CAUTION Make sure cabling is NOT pinched during installation Fig 8 ...

Page 14: ...ht M handrail covers with the ribbing plate into the square hole in the left and right handrail as shown in Fig 9 1 b Tighten the left L and right M handrail cover using screw i and nylon nut m c Fasten POP Pin n into the adjustable console neck assembly Square hole Ribbing Plate ...

Page 15: ... the Circuit Breaker will operate the Circuit Breaker will trip and open the circuit If this should occur please wait 10 minutes and then reset the Circuit Breaker by cycling the Circuit Breaker to the off position 0 then back to the on position l If it does not reset or the Circuit Breaker operates again please contact Light Gait Service department at 1 800 332 9255 Fig 9 1 GK2200T Treadmill Fron...

Page 16: ...e below SAFETY KEY AS SHIPPED b Unwind safety key and cord from plate c Attach Safety Key magnet to front of Center Pod as shown below d Attach Safety Key clip to plate located on Console Rack when not working out e Attach clip to clothing at the beginning of any workout CAUTION Read treadmill Owners Manual before attempting any workout ...

Page 17: ...Assembly Instructions 16 SAFETY KEY INSTALLED CLIP MAGNET LANYARD ATTACHED TO PLATE PLATE ...

Page 18: ...Assembly Instructions 17 Electrical Schematic www LiteGait com 800 332 9255 1 480 829 1727 2012 Mobility Research Inc Specifications subject to change 09252012 ...

Reviews: