LAE Electronic Control
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/
Up Button
Stand-By
Button
HOW TO CHANGE THE “SET POINT”
WHY:
THE SET POINT IS THE TEMPERATURE AT WHICH THE
COMPRESSOR WILL SHUT OFF.
Please note that the “set point” IS NOT the cabinet
holding temperature.
HOW:
A.
To see the set point, press and hold the info button
and the stand-by button at the same time.
“ScL” will appear. See image 1.
B.
Push the up button three times until “SP”
appears. See image 2.
C.
Press and hold the info button to see the
“set point”. See image 3.
D.
While pressing and holding the info button ,
press the up or down button to change
the “set point”.
E.
Once the “set point” has been set correctly release the
info button .
Wait 30 seconds for the display to show temperature.
See image 4.
1
2
3
4
Compressor
Running
Activation of 2nd
Parameter Set - NA
Alarm - NA
Cabinet in Defrost
Evaporator Fan
Running
LAE Control Icons
May need to unlock control.
ALL OTHER SETTINGS ARE FACTORY PRE-SET AND SHOULD NOT BE CHANGED.
If you have any questions, please call TRUE technical service.