Symptom
Probable
Cause
Corrective Action
Recommended Tools
NO DISPLAY
600EA
Power Issues
Control Panel
Power Supply
Cables
•
Set meter to AC voltage and test wall
outlet to 120 VAC.
•
Turn power switch on
•
Does power switch lamp come on?
•
Yes – go to control panel.
•
No- remove rear cover.
•
Check voltage input to switch, is it 120
VAC? If yes – replace switch. If no –
continue on.
•
Check voltage at end of power cord.
•
No voltage? Replace cord.
•
Check fuse in power inlet.
•
Replace fuse or replace power inlet and
wires.
--------
•
Check connection to the display.
•
Reseat connection.
•
Set meter to DC volts, unplug display
and check voltage between pin 1and pin
2.
•
If 12VDC is present – replace control
panel.
--------
•
Check voltage between pin 2and pin 3at
the power supply.
•
If 12 VDC present – replace power
supply.
--------
•
Perform a continuity check on the cables
leading to the control panel.
•
Replaced damaged cables.
Multi-meter
Page 13
Support Services 800-883-8783
Mon-Fri 8:30am-5:00pm Central Time Zone
Fax: 636-272-7148
Summary of Contents for 600EA
Page 17: ...WIRING DIAGRAMS TAE 600 Page 16 TAE 750 Page 17 TE 750 Page 18 Page 15 ...
Page 18: ...TRUE TAE 600 WIRING DIAGRAM Page 16 ...
Page 19: ...Page 17 TRUE TAE 750 WIRING DIAGRAM ...
Page 20: ...Page 18 TRUE TE 750 WIRING DIAGRAM ...
Page 21: ...True Armed Elliptical 600B Exploded Diagram Page 20 Parts List Page 21 Page 19 ...
Page 22: ...TRUE TAE 600 PARTS DIAGRAM Page 20 ...
Page 25: ...True Armed Elliptical 750 Exploded Diagram Page 24 Parts lists Page 25 Page 23 ...
Page 26: ...TRUE TAE 750 PARTS DIAGRAM Page 24 ...
Page 30: ...TRUE TE 750 PARTS DIAGRAM Non Cartridge Bearings Page 28 ...
Page 33: ...TRUE TE 750 PARTS DIAGRAM Cartridge Bearings Page 31 ...
Page 36: ...Page 34 ...
Page 37: ...True Fitness Removal Replacement 500R 500U 600U 600R Page 35 ...