Rev C, March 8, 2018 

Manual Number 9019049

 

 

 

1.1 INTRODUCTION 

The model TC2000 Series Static Electrical Power Converter is a lightweight power converter that 
translates an aircraft alternating current (AC) input of 115 volts at 360-800 Hertz to a 28 volt 
direct current (DC) output. Additionally the TC2000 can be bench operated on AC Mains with 
115 or 230 volts at 47-65 Hz input and provide a 28 volt direct current (DC) output (see Note 1 
below).  

The wide input operating voltage and frequency make the TC2000 suitable for nearly any 
common business or commercial aircraft which provides 100-125 VAC between 360-800 Hertz. 
The output of 71 amps @ 28 VDC produces 2000 watts of power to supply avionics, 
instrumentation, seating, personal charging, lighting, and many other applications. The TC2000 
Series Static Converter is FAA certified to TSO-C71 and tested to rigorous environmental 
standards and levels of RTCA DO-160G. The small size and light weight in conjunction with its 
installation flexibility (inside or outside the pressure vessel) make it an ideal choice for aircraft 
power needs while reducing the challenges associated with other similar products.  

Highlighted features include short circuit protection, overload capability, low voltage shut-down, 
temperature monitoring, a self-resettable over-temperature disable and a remote on/off function. 
The TC2000 Series has a robust Military-rated circular connector, and the rugged extrusion that 
houses the unit is designed to help dissipate heat and provide mechanical strength against 
vibration or other possibilities of damage. Two independent fans allow for a smaller unit and 
quiet operation, and keep the internal components cool extending the life of the unit. 

1.2 TECHNICAL 

SPECIFICATIONS 

Electrical Attributes:

 

Model TC2000 

Input Voltage 

Aircraft: 115VAC nominal, 360-800 Hz. 
AC Mains: 115VAC or 230VAC, 47 to 65 Hz. (

Note 1)

 

Input Current (full load) 

22 Amps nominal; 28 Amps max 

Input Current (unit off) 

2 Amps 

Recommended Input Circuit Breaker 

30 Amps (for 115VAC aircraft use) 

Output Voltage 

28VDC ± 0.5 VDC 

Output Power 

2000 watts (28VDC @ 71 Amps rated) 

Efficiency 88% 

nominal 

Table 1.1 

Physical Attributes:

 

Model TC2000 

Weight: 

9.9 lbs [4,49 kg] 

Dimensions:  
(not including connector mate) 

14.00 inches x 6.32 inches x 3.46 inches (LxWxH) 
[35,5 x 16,1 x 8,8 cm] 

Mating Connector (and cable clamp):  MCI P/N 9018993-1 and 9018550-2 
Mounting: 

Base mount – orientation not critical 

Table 1.2 

Note 1: The TC2000 has not been tested to UL, CE, or other ground regulatory requirements. Powering from AC mains 
is intended for testing or temporary use only.  

 

 

Summary of Contents for TC2000 Series

Page 1: ...lectrical Power Converter True Blue Power is a division of Mid Continent Instrument Co Inc Mid Continent Instrument Co Inc dba Mid Continent Instruments and Avionics 9400 E 34th Street N Wichita KS 67226 Manual Number 9019049 PH 800 821 1212 FX 316 630 0723 Rev C March 8 2018 ...

Page 2: ...nts concerning this manual Although every effort has been made to keep it free of errors some may occur When reporting a specific problem please describe it briefly and include the manual part number the paragraph figure table reference and the page number Send your comments to True Blue Power c o Mid Continent Instrument Co Inc Attn Technical Publications 9400 E 34th Street N Wichita KS 67226 USA...

Page 3: ...N DETAIL Revision Date Approved Detail A 12 28 2017 BAW Initial release B 01 26 2018 BAW Corrected formatting issues Incorporated FAA comments C 03 08 2018 JRC Changed paragraph 3 3 2 3 pin E to pin A Added note page 5 on ground regulatory requirements ...

Page 4: ...KING AND INSPECTING EQUIPMENT 8 3 3 CABLE HARNESS 8 3 3 1 Wire Gauge Selection 8 3 3 2 Pin Assignment Information 9 3 3 3 Example Wiring Diagrams 10 3 3 4 Harness Verification 10 3 4 MOUNTING 12 3 5 INSTALLATION COMPLETION 13 3 6 INSTALLATION CAUTION 13 SECTION 4 OPERATION 14 4 1 ELECTRICAL PERFORMANCE 14 4 2 PROTECTIVE FEATURES 14 4 2 1 Remote On Off 14 4 2 2 Over Temperature 14 4 2 3 Short Circu...

Page 5: ...hort circuit protection overload capability low voltage shut down temperature monitoring a self resettable over temperature disable and a remote on off function The TC2000 Series has a robust Military rated circular connector and the rugged extrusion that houses the unit is designed to help dissipate heat and provide mechanical strength against vibration or other possibilities of damage Two indepe...

Page 6: ...owever installation locations where the unit could be subject to standing or direct water exposure should be avoided The unit can be mounted in any orientation Clearance should be provided for the mating connector and may require as much as five inches past the unit connector to allow for back shell access to the connector 2 3 ROUTING OF CABLES The wires and cable bundle associated with the unit a...

Page 7: ...rticle on or in a specific type or class of aircraft must determine that the aircraft installation conditions are within the TSO standards TSO articles must receive additional installation approval prior to being operated on each aircraft The article may be installed only according to 14 CFR Part 43 or the applicable airworthiness requirements Figure 2 1 Derated Output Power versus Altitude Figure...

Page 8: ...quipment a Mating Connector cable clamp MCI P N 9018993 1 and 9018550 2 Equipment not provided a Mounting Hardware four 4 20 pan head screws lock washers optional b Cable Harness Wire See Section 3 3 for specifications 3 3 CABLE HARNESS Construct the cable harness with regards to the instructions below and using Figures 3 3 3 5 and Wiring Diagram of Table 3 3 Refer to Section 2 Pre Installation Co...

Page 9: ...ed return bus if it is desirable to have a 28V DC bus independent and isolated from the aircraft DC bus Note Use of a circuit breaker on the DC output is optional For the full output of 2000W a single circuit breaker current of 75 Amp maximum is recommended If multiple branching circuits are connected to the output then the total rating of all circuit breakers should not exceed 75 Amps 3 3 2 3 CON...

Page 10: ...e than one TC2000 can be connected in parallel to provide more than 2000 Watts of power conversion to 28 VDC Contact Mid Continent Instruments True Blue Power for additional information on this feature If the parallel operation feature is not being used this pin should remain unconnected 3 3 3 Example Wiring Diagrams See Figures 3 4 and 3 5 for examples of potential wiring diagram options for inst...

Page 11: ... 8 V D C O U T P U T G G F Figure 3 4 Typical TC2000 Aircraft Wiring Installation Constant On T C 2 0 0 0 B B E E A A C C D D 1 1 5 V A C I N P U T 3 0 A C I R C U I T B R E A K E R O F F O N C A S E A T T A C H E D T O A I R F R A M E E N A B L E 7 5 A C I R C U I T B R E A K E R 2 8 V D C O U T P U T G G F Figure 3 5 Typical TC2000 Aircraft Wiring Installation Remote On Off ...

Page 12: ...s designed for base mounting only in any orientation Four 20 mounting holes should be provided in the aircraft in accordance with Figure 3 6 Secure the unit with four 20 pan head screws or equivalent A lock washer under the head of each screw is recommended 3 75 5 50 13 25 11 75 14 00 4X Ø 0 281 Mounting Holes 3 45 6 32 Figure 3 6 TC2000 Series Static Converter Outline Drawing ...

Page 13: ...verification Verify the output of the unit at the terminating end of the cable with a multi meter to ensure proper voltage and polarity Once verified installation can be completed and functionality of the remote on off feature if used should be checked 3 6 INSTALLATION CAUTION CAUTION Do not connect the output of the TC2000 Series Static Converter to the output of any other Converter or damage wil...

Page 14: ...of the unit The unit can be similarly disabled by removing the ground signal open circuit to the same pin 4 2 2 Over Temperature The TC2000 Series Static Converter incorporates an internal temperature sensing device that continually provides monitoring and feedback to the control circuits When the unit senses an internal condition that exceeds maximum temperature ratings the output is disabled and...

Page 15: ...ude Low Temperature High Temperature Altitude 4 4 5 2 4 5 4 4 6 1 Category C3 Operating Low Temp 55C Operating High Temp 70C Altitude 35 000 ft Temperature Variation 5 Category S2 Humidity 6 Category B Operational Shock and Crash Safety 7 Category B Vibration 8 Category R Curve C C1 RCC1 Explosion 9 Category X Waterproofness 10 Category X Fluids 11 Category X Sand and Dust 12 Category X Fungus 13 ...

Reviews: