Rev C, March 8, 2018
15
Manual Number 9019049
5.1
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS
No periodic scheduled maintenance or calibration is necessary for continued airworthiness of
the TC2000 Series Static Converter. If the unit fails to perform to specifications, the unit must be
removed and serviced by Mid-Continent Instruments and Avionics or their authorized designee.
5.2 ENVIRONMENTAL
QUALIFICATION
STATEMENT
NOMENCLATURE:
Static Electrical Power Converter
MODEL NUMBER:
TC2000
TSO NUMBER:
C71
MANUFACTURERS SPECIFICATIONS:
Test Specification (TS) 714, Test Data Sheet (TDS) 714
QUALIFICATION STANDARD
:
RTCA DO-160G
CONDITIONS SECTION
DESCRIPTION
OF
TEST
Temperature and Altitude
Low
Temperature
High
Temperature
Altitude
4
4.5.2
4.5.4
4.6.1
Category C3
Operating Low Temp = -55C
Operating High Temp = +70C
Altitude = +35,000 ft.
Temperature Variation
5
Category S2
Humidity 6
Category
B
Operational Shock and
Crash Safety
7 Category
B
Vibration
8
Category R; Curve C, C1 [(RCC1)]
Explosion 9 Category
X
Waterproofness 10
Category
X
Fluids 11
Category
X
Sand and Dust
12
Category X
Fungus 13
Category
X
Salt Spray
14
Category X
Magnetic Effect
15
Category A
Power Input
16
Category A(CF)
Voltage Spike
17
Category A
Audio Frequency Conducted
Susceptibility
18 Category
R(CF)
Induced Signal Susceptibility
19
Category X
Radio Frequency Susceptibility 20
Category
X
Emission of Radio Freq Energy
21
Category B
Lightning Induced Transient
Susceptibility
22 Category
X
Lightning Direct Effects
23
Category X
Icing 24
Category
X
ESD 25
Category
A
Flammability 26 Category
X