Store the product in clean, dry conditions away from heat and direct sunlight; avoid contact 
with metals, solvents, oils or greases and strong detergents. When the product is not in use 
please store in the black carrier case provided.  

Gently wash the ultrasound insert after use. Please use alcohol wipes, warm soapy water or 
similar, until all visible foreign matter and residue are removed.  

Mild detergents or enzymatic cleaning agents may be used on the insert in accordance with 
the manufacturer's instructions and at the proper dilution. The detergent must not contain 
skin or mucous membrane irritants. 

Please do not use any of the following when cleaning the AirSim product range 

 

Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g. Cidex®), 

 

Ethylene oxide, phenol-based cleaners or iodine-containing cleaners 
 

In response to the recent COVID-19 pandemic, we recommend this additional step to ensure 
the product is fully sanitised: 

 
Use alcohol spray (minimum 75%) and wipe off. Repeat this for 3-4 times to ensure to kill 
the virus completely.  

 

 

Warranty

 

TruCorp warrants this unit to be free of defects in materials and workmanship and to give 
satisfactory service for a period of 1-year from the date of delivery. This ensures that our 
customers receive maximum coverage on each product. If the unit should malfunction it 
must be returned to the factory for evaluation. Upon examination by TruCorp, if the unit is 
found to be defective it will be repaired or replaced at no charge.  

TruCorp will pay for the freight/delivery and the actual parts needed free of charge if any 
part of the product fails within the 1-year period.  

However, these warranties are VOID, if; the unit shows evidence of having been tampered 
with or shows evidence of having been damaged by excessive heat, the use of sharp 
instruments, misapplication, misuse or other operating conditions outside of TruCorp

’ s 

control. Components which wear or are damaged by misuse are not warranted and will be 
charged for if repair has been approved. Please ensure to strictly follow the recommended 

Summary of Contents for TruUltra TruIV Block

Page 1: ... is easily transportable and can be set up in less than 5 minutes perfect for a busy teaching environment The TruUltra material known for its durability will withstand repeated use of approximately 4000 needles before needing replaced TruIV Block is ideal for emergency medicine radiology surgical training programs ultrasound training programs simulation centres medical education facilities and ult...

Page 2: ... Product specifications 3 Package contents 3 Recommended equipment sizes 3 Initial Set Up Fluid Insertion 4 IV cannulation 8 Removing Fluids 9 Replacing the ultrasound insert 9 Care and maintenance 9 Warranty 10 ...

Page 3: ...contents 1x TruIV Block unit TIV100 1x TruIV Block carrier case 1x USB pen drive user manual 2x tubes with luerlock connectors for fluid insertion removal 1x 60ml syringe Recommended equipment sizes Size 20G needle for IV cannulation Please do not use needles larger than 18G This can cause permanent damage to the model and may void the product warranty please refer to page 10 for warranty informat...

Page 4: ...asound image is obtained Any brand of ultrasound machine can be used with this model Adjust the depth and gain controls as required until the desired image is obtained Please follow these next steps to insert fluid into the model 1 Prepare approx 200ml of artificial blood and add to a luer lock syringe We recommend purchasing TruCorp s artificial blood concentrate product code CVB250 not supplied ...

Page 5: ... carefully into an empty container 4 Ensure the 2 switches on both connectors highlighted by the blue arrows below are open to allow the fluid to exit through the tubes When open the switches are positioned parallel to the block Insert fluid here for IV Cannulation in superficial veins Insert fluid here for IV Cannulation in deep veins Fluid will exit here when sufficient fluid has been inserted i...

Page 6: ...pper blue IN connector 6 Slowly push the blood through the syringe until it is seen exiting the tube connected to the upper blue OUT port with no air bubbles 7 Close the switch on the upper blue OUT tube for the superficial veins by turning it so it no longer aligns parallel to the model ...

Page 7: ...id for the deep veins attach the blood filled syringe to the upper grey IN connector 9 Slowly push the blood through the syringe until it is seen exiting the tube connected to the lower grey OUT port with no air bubbles ...

Page 8: ...sing ultrasound to target the veins for vascular access procedures 3 In line with clinical guidelines ultrasound gel should be applied to the ultrasound probe prior to use to ensure a high quality ultrasound image is obtained 4 Features 4 superficial veins with diameters of 4mm 5mm 6mm and 8mm 5 Features 4 deep veins with diameters of 4mm 2 x 6mm and 8mm 6 Correct needle placement can be visually ...

Page 9: ...To remove blood from the superficial veins attach a syringe to the upper blue OUT port and gently withdraw until no more fluid remains 2 To remove blood from the deep veins attach a syringe to the upper grey OUT port and gently withdraw until no more fluid remains Replacing the ultrasound insert 1 Important Please do not discard the base or tubes supplied with your original model A replacement ins...

Page 10: ...s fully sanitised Use alcohol spray minimum 75 and wipe off Repeat this for 3 4 times to ensure to kill the virus completely Warranty TruCorp warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 1 year from the date of delivery This ensures that our customers receive maximum coverage on each product If the unit should malfunction it...

Page 11: ... if third party products are seen to have damaged or caused failure of the TruCorp models Please direct all warranty and repair inquiries to TruCorp Ltd 33 Waringstown Road Lurgan Co Armagh BT66 7HH N Ireland info trucorp com Tel 44 0 28 3888 2714 ...