Self-regenerating TruUltra material has been designed to facilitate 4000+ needle 

penetrations which will disappear by up to 90% after a 24h resting period (500+ 

 needles for each of the 8 veins) 

9.

 

A 20G needle should be used for IV techniques for optimal performance. Using a needle 

larger than this may void the warranty if damage is caused to the model (please refer to 

page 10 for warranty information) 

 

Removing Fluids 

This is recommended when the model is being transported, or kept in storage for 
extended periods of time

 (keeping fluid in the system short-term will not damage the 

model) 

1.

 

 

To remove blood from the 

superficial

 veins, attach a syringe to the 

upper

 

blue

 

OUT

’ port and gently withdraw until no more fluid remains

 

2.

 

To remove blood from the 

deep

 veins, attach a syringe to the 

upper

 

grey

 

OUT

’ port 

and gently withdraw until no more fluid remains

 

 

Replacing the ultrasound insert  

1.

 

Important: 

Please do not

 

discard the base or tubes supplied with your original model. A 

replacement insert includes only the block which IV cannulation is practised upon 

 the 

base and tubing from your original order is re-used 

2.

 

Lift the ultrasound insert off the base (not attached via glue or connectors etc.)

 

3.

 

Align the new insert onto the existing base and re-position

 

4.

 

Please ensure the insert sits firmly with sufficient grip to avoid the insert moving during 
training

 

 

 

 

 

 

Care and maintenance

 

 

Summary of Contents for TruUltra TruIV Block

Page 1: ... is easily transportable and can be set up in less than 5 minutes perfect for a busy teaching environment The TruUltra material known for its durability will withstand repeated use of approximately 4000 needles before needing replaced TruIV Block is ideal for emergency medicine radiology surgical training programs ultrasound training programs simulation centres medical education facilities and ult...

Page 2: ... Product specifications 3 Package contents 3 Recommended equipment sizes 3 Initial Set Up Fluid Insertion 4 IV cannulation 8 Removing Fluids 9 Replacing the ultrasound insert 9 Care and maintenance 9 Warranty 10 ...

Page 3: ...contents 1x TruIV Block unit TIV100 1x TruIV Block carrier case 1x USB pen drive user manual 2x tubes with luerlock connectors for fluid insertion removal 1x 60ml syringe Recommended equipment sizes Size 20G needle for IV cannulation Please do not use needles larger than 18G This can cause permanent damage to the model and may void the product warranty please refer to page 10 for warranty informat...

Page 4: ...asound image is obtained Any brand of ultrasound machine can be used with this model Adjust the depth and gain controls as required until the desired image is obtained Please follow these next steps to insert fluid into the model 1 Prepare approx 200ml of artificial blood and add to a luer lock syringe We recommend purchasing TruCorp s artificial blood concentrate product code CVB250 not supplied ...

Page 5: ... carefully into an empty container 4 Ensure the 2 switches on both connectors highlighted by the blue arrows below are open to allow the fluid to exit through the tubes When open the switches are positioned parallel to the block Insert fluid here for IV Cannulation in superficial veins Insert fluid here for IV Cannulation in deep veins Fluid will exit here when sufficient fluid has been inserted i...

Page 6: ...pper blue IN connector 6 Slowly push the blood through the syringe until it is seen exiting the tube connected to the upper blue OUT port with no air bubbles 7 Close the switch on the upper blue OUT tube for the superficial veins by turning it so it no longer aligns parallel to the model ...

Page 7: ...id for the deep veins attach the blood filled syringe to the upper grey IN connector 9 Slowly push the blood through the syringe until it is seen exiting the tube connected to the lower grey OUT port with no air bubbles ...

Page 8: ...sing ultrasound to target the veins for vascular access procedures 3 In line with clinical guidelines ultrasound gel should be applied to the ultrasound probe prior to use to ensure a high quality ultrasound image is obtained 4 Features 4 superficial veins with diameters of 4mm 5mm 6mm and 8mm 5 Features 4 deep veins with diameters of 4mm 2 x 6mm and 8mm 6 Correct needle placement can be visually ...

Page 9: ...To remove blood from the superficial veins attach a syringe to the upper blue OUT port and gently withdraw until no more fluid remains 2 To remove blood from the deep veins attach a syringe to the upper grey OUT port and gently withdraw until no more fluid remains Replacing the ultrasound insert 1 Important Please do not discard the base or tubes supplied with your original model A replacement ins...

Page 10: ...s fully sanitised Use alcohol spray minimum 75 and wipe off Repeat this for 3 4 times to ensure to kill the virus completely Warranty TruCorp warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 1 year from the date of delivery This ensures that our customers receive maximum coverage on each product If the unit should malfunction it...

Page 11: ... if third party products are seen to have damaged or caused failure of the TruCorp models Please direct all warranty and repair inquiries to TruCorp Ltd 33 Waringstown Road Lurgan Co Armagh BT66 7HH N Ireland info trucorp com Tel 44 0 28 3888 2714 ...

Reviews: