TRU Components 2256179 Operating Instructions Manual Download Page 3

•  The relay card consists of sensitive electronic components. An improper handling 

can lead to their destruction. Particularly damaging are electrostatic discharges, 

induced voltage spikes and equalising currents between different voltage 

potentials.
Before handling the card, touch an electrically earthed object, e.g. a metal PC 

housing. Grasp the card only at the edges. Never touch electronic components 

or conducting paths to the card. Before connecting or disconnecting power 

cords,always switch off the power supply of the relay card and of the connected 

devices or separate the relay card from the PC.

•  For the purpose of touch and function protection, install the relay card in a 

housing. The mounting enclosure ”Phoenix Contact” of the series UMK is provided 

for installation on a DIN rail (see chapter ”Recommended Accessories”at the end 

of these operating instructions).

•  Do not overload the relay contacts. Never connect a higher voltage than 24 V/DC 

to the relay contact; the current may be at most 8 A.

•  Consult an expert when in doubt about the operation, safety or connection of the 

appliance.

• 

Maintenance, modifications and repairs must only be completed by a technician 

or an authorised repair centre.

•  If you have questions which remain unanswered by these operating instructions, 

contact our technical support service or other technical personnel.

Operation

a) Connections and Control Elements

USB:  

USB (Type B socket): Interface for communication and power supply

UB EXT:    Screw terminals for external power supply if no sufficient power supply is available 

over USB

VREL:  

Jumper for selecting the power supply (via USB or screw terminals UB EXT)

+

UB 5V/DC

USB

EXT

LED1

LED2

LED3

LED4

K1

K2

K3

K4

yal

e

Rx

4

B

S

U

dr

ao

B

in

ort

cel

E

dar

no

C

E

S

c

COM NC NO COM NC NO COM NC NO COM NC NO

76mm

68mm

m

m4

6

m

m2

7

m

m5,

3

REL1

REL2

REL3

REL4

USB

UB EXT

VREL

b) Installation of Software/Driver

  Before the relay card is connected to the PC, first install the software and the driver.

 

To ensure that the most recent version is used, this is not included in the package; 

rather,  you  can  find  the  corresponding  software  in  the  product’s  download  at 

 

www.conrad.com.

The following files are available for download:

•  Software for use of the relay card as timer switch and presence simulator
•  Sample source code for VB2010 and Visual C++ 6.0
•  Documentation for use of CP210xRuntimeDLL
•  Driver

After the download, start the downloaded software. After the programme files are copied, the 

driver installation is called up automatically. Follow the respective instructions. You can find 

current drivers at www.Silabs.com if needed.
It is recommended to restart the PC afterward.
Now connect the relay card with a free USB port of your computer. For this purpose, the relay 

card has a USB interface (USB-B socket). Upon initial connection, Windows recognizes the 

new hardware and completes the driver installation. Depending on the operating system, this 

process can require several minutes.

 Operating Instructions

USB 4-Channel Relay Card

Item No. 2256179

Intended Use

The relay card contains four potential-free relays with changeover contacts in order to switch 

electrical devices connected to it.
The relays are controlled via USB (requires Windows operating system from Windows XP).
The control software (available by free download) enables the on/off switching of the relays, 

switch state detection, presence simulation (random switching of the relays) and timer function 

with 10 adjustable switch times (daily and weekly programme).
The source code examples (Visual Basic.net, VC++), which are also available by download, 

can be adjusted and expanded according to the requirements. Moreover, the control of the 

relays is illustrated using the CP210xRuntimeDLL. The examples do not show all options; 

rather, they should only clarify the functioning principle of the control commands.
It is imperative that you observe the safety instructions as well as the maximum allowable 

operating and environmental conditions given in the technical data.
It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in 

bathrooms, must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use 

the product for purposes other than those described above, the product may be damaged. In 

addition, improper use can result in short circuits, fires, electric shocks or other hazards. Read 

the instructions carefully and store them in a safe place. Make this product available to third 

parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company 

names and product names are trademarks of their respective owners. All rights reserved.

Delivery Content

•  USB 4-channel relay card
•  Operating instructions

Up-to-date Operating Instructions           

Download the latest operating instructions at www.conrad.com/downloads or 

scan the QR code shown. Follow the instructions on the website.

Explanation of Symbols

  The symbol with the lightning in the triangle is used if there is a risk to your health, 

e.g. due to an electric shock.

  The symbol with the exclamation mark in the triangle is used to indicate important 

information in these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and advice on operation.

Safety Instructions

Read the operating instructions carefully and especially observe the safety 

information. If you do not follow the safety instructions and information on 

proper handling in this manual, we assume no liability for any resulting 

personal injury or damage to property. Such cases will invalidate the warranty/

guarantee.

•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. This may become 

dangerous playing material for children.

•  Protect the appliance from extreme temperatures, direct sunlight, strong jolts, high 

humidity, moisture, flammable gases, steam and solvents.

•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed 

if the product:

 - is visibly damaged,
 - is no longer working properly,
 - has been stored for extended periods in poor ambient conditions or
 - has been subjected to any serious transport-related stresses.

•  Please handle the product carefully. Jolts, impacts or a fall even from a low height 

can damage the product.

Summary of Contents for 2256179

Page 1: ...kten um daran angeschlossene elektrische Verbraucher zu schalten Die Ansteuerung der Relais erfolgt ber USB erfordert Windows Betriebssystem ab Windows XP Die Steuersoftware per kostenlosem Download v...

Page 2: ...Relais kann ein externer Stromkreis geschaltet werden NO Schlie erkontakt NC ffnerkontakt COM Mittelkontakt gemeinsamer Anschluss e Erstellen eigener Software Die Relaiskarte wird ber das USB Interfa...

Page 3: ...to it The relays are controlled via USB requires Windows operating system from Windows XP The control software available by free download enables the on off switching of the relays switch state detec...

Page 4: ...rom the mains before each cleaning Do not use any aggressive cleaning agents rubbing alcohol or other chemical solutions as they can cause damage to the housing and malfunctioning Clean the product wi...

Page 5: ...d allumer teindre les appareils lectriques connect s Le contr le du relais s effectue par USB le syst me d exploitation Windows requis doit tre Windows XP ou toute version sup rieure Le logiciel de c...

Page 6: ...t ferm COM contact central connexion commune e Cr ation de votre propre logiciel La carte relais est contr l e via l interface USB en utilisant la DLL CP210xRuntimeDLL Dynamic Link Library Pour vous a...

Page 7: ...over vier potentiaalvrije relais met wisselcontacten om daarop aangesloten elektrische verbruikers te schakelen De aansturing van het relais geschiedt via USB Windows besturingssysteem vereist vanaf W...

Page 8: ...orden geschakeld NO Maakcontact NC Verbreekcontact COM Middelcontact gemeenschappelijke aansluiting e Samenstellen van eigen software De relaiskaart wordt via de USB interface met gebruikmaking van CP...

Reviews: