1.1 K9000 2.0 System Specifications
SYSTEM WITHOUT ON BOARD HOT WATER UNIT
Power
208/240V
16 AMP (10 AMP max load)
WATER Inlet Pressure (Min)
40psi / 275kpa
Hot
½” Ball valve
Cold
½” Ball valve
WATER Inlet Pressure (Max)
72psi / 500kpa
Hot
½” Ball valve
Cold
½” Ball valve
COLD WATER Inlet temperature
Minimum
5 Degrees Celsius
Maximum
30 Degrees Celsius
HOT WATER Inlet temperature
Minimum
55 Degrees Celsius
Maximum
65 Degrees Celsius
Factory Set water temperature
35 Degrees Celsius at wash gun
WATER Maximum Operating Pressure
50psi / 350kpa
Factory set via water regulator
FILTRATION
Primary
Stainless steel mesh filter
Secondary
Vinidex DBA Lic. No. WMKA20071
Back Flow Prevention Device
Connections to be protected by a “high hazard” backflow prevention device. i.e.
“RPZ or Registered “Air-GAP” Recommended Watts 009M3-AUS RP 15 0r 20mm
AS2845.1 Lic WMKA1335
WASTE
2” DIA Outlet as well as, a minor trade waste application to be made to the local
water regulator (As per local requirements)
SYSTEM WITH ON BOARD HOT WATER UNIT
Power Instant Hot Water or
208/240V
16 AMP (10 AMP max load) for dog
wash as well as External
(dependent
upon inlet water temperature and # of
dog wash units to be installed) (with
instant electric hot water service)
Power Hot Water Storage Tank
208/240V
40 AMP (32 AMP max load)
WATER Inlet Pressure (Min)
40psi / 275kpa
Cold
½” Ball valve
WATER Inlet Pressure (Max)
72psi / 500kpa
Cold
½” Ball valve
COLD WATER Inlet temperature
Minimum
45 Degrees Fahrenheit
Maximum
85 Degrees Fahrenheit
Factory Set water temperature
32-34 Degrees Celsius at wash gun
WATER Maximum Operating Pressure
50psi / 350kpa
Factory set via water regulator
FILTRATION
Primary
Stainless steel mesh filter
Secondary
Vinidex DBA Lic. No. WMKA20071
Back Flow Prevention Device
Connections to be protected by a
“high hazard” backflow prevention device. i.e.
“RPZ or Registered “Air-GAP” Recommended Watts 009M3-AUS RP 15 0r 20mm
AS2845.1 Lic WMKA1335
WASTE
2” DIA Outlet as well as, a minor trade waste application to be made to the local
water regulator (As per local requirements)
Tundish
Required for hot water relief pipe (storage tank system only)
DIMENSIONS / WEIGHT
Dimensions
Length 2150mm / Height 1850mm / Depth 600mm
Weight
K9000 2.0
– 285kg
APPROVALS
CSA Approved
– Each machine is CSA inspected and labelled
Risk assessment performed by IAPMO (NATA accredited laboratory)
CE conformity with the following European Union Directives: EMC Directive 2004/108/EC & Low Voltage Directive
2006/95/EC
IEC 61000-6-3:2006 Electromagnetic compatibility (EMC)
– Part 6.3: Generic standards – Emission standard for residential,
commercial and light-industrial environments
AS/NZS 60335.2.75:2005 + Admt
2009 in relation to vending machines AS 60204.1:2005 ‘Safety of machinery – Electrical
equipment of machines, General Requirements’
IEC 61000-6-1: 2005 Electromagnetic compatibility (EMC) Generic standards. Immunity for residential, commercial and light-
industrial environments.
ATS 5200.101:2005
– Strength of Assembly
EPA Registered Noise tested rating of 66dba @ 4 meters
USAGES
Water Usage: Average 10 litres per minute or 50 litres per wash (5 minutes)
Average power usage per wash cycle is .76kwh (dependent on hot water source)