2.3 Connecting the Power
– For Your Electrician
The K9000 2.0 needs to be hardwired to the switch board on its own circuit. The size of the
circuit depends on the specific specification of your K9000 2.0, refer to the rating plate
located inside the cabinet to confirm your maximum load. This circuit needs to have a GFCI
(Ground Fault-Circuit Interrupter) on the switch board as the K9000 2.0 has no ground fault
protection.
The following bullet points highlight the necessary electrical safety requirements you
need as part of the electrical installation of your K9000 2.0:
•
*Branch Circuit Breaker in site Switch Board
•
*GFCI in site Switch Board
•
External Disconnect Device, between site switch board & dog wash
*Size of circuits, breakers etc dependent on specifications of your K9000 2.0, refer to the
rating plate located inside the cabinet.
The photo below left is the main electrical cable inside the dog wash. It enters through the
gland at the bottom of the dog wash, close to ground level. Run the power cable in 25mm
flexible conduit as there is a socket already installed into the bottom of the breaker box.
1000mm
Isolate
Neutral
Ground
Wires
Hot 1
Hot 2
The below picture is a
close up of the breaker
box with wires labelled
to assist your electrician.
Summary of Contents for K9000 2.0