background image

 

Troyka Med Inc 

IOSB Mah. 2284. Cad No: 48 Yenimahalle Ankara TURKEY  

Tel:

 +90 5325128580- [email protected] – 

www.troykamed.com

 

T-280 MRI Conditional Dom Camera Op. Man. Pub. 022018 Pub. No: 0 Rev:0  

Introduction 

 

Thank you or purchasing the T-280 MRI Conditional Dom Camera. This product is manufactured and 
tested to the highest standards and is guaranteed MR Conditional up to 3 Tesla.    

This product is manufactured by Troyka Med Inc. at our factory based is Ankara, Turkey, to BS EN 
ISO 13485:2016   

To ensure that you obtain maximum benefit from the T-280 MRI Dom Camera, please take a few 
minutes  to  read  the  enclosed  information  regarding  operation,  service  and  maintenance.  After 
reading this manual, store it in a safe place for future reference.  

If  you  have  any  problems  in  the  meantime  or  would  like  any  advice  about  this  or  any  other  MR 
products from the Troyka Med range, please contact us at the following address 

 

 

Troyka Med Inc. 

Tel:    

+90 312 2650096 

E-mail:  

[email protected] 

Website:   www.troykamed.com 

 

 

 

 

 

 

 

Protect from 

direct sunlight 

 

Protect from rain and 

humidity 

 

MRI conditional up to 3 Tesla 

 

Read user manual 

 

Manufacturer 

 

ISO13485 

ISO 9001 

Class I medical devises 

 

 

Summary of Contents for T-280 MRI

Page 1: ... No 48 Yenimahalle Ankara TURKEY Tel 90 5325128580 info troykamed com www troykamed com T 280 MRI Conditional Dom Camera Op Man Pub 022018 Pub No 0 Rev 0 OPERATORS MANUAL T 280 MRI Conditional Dom Camera MRI CONDITIONAL TO 3 T 0 TESLA ...

Page 2: ...485 2016 To ensure that you obtain maximum benefit from the T 280 MRI Dom Camera please take a few minutes to read the enclosed information regarding operation service and maintenance After reading this manual store it in a safe place for future reference If you have any problems in the meantime or would like any advice about this or any other MR products from the Troyka Med range please contact u...

Page 3: ...table risks to the patient medical staff or other persons within the MR environment 1 2 General Safety Information and Intended Use The MRI dom camera must only be operated by personnel property trained in MRI safety The MRI dom camera must only be operated by personnel properly trained in identifying interference problems such as artifacts streaks and distortions in image data It is required that...

Page 4: ...the dom camera possible electric shock or fire Don t handle the power cable with wet hands High voltages present could cause lethal electric shock Warning Should any foreign substances enter the device such as liquid metal chips or dust immediately turn off power to the Interface Unit Under no circumstances shall tools or foreign objects be inserted into the device as this could result in failure ...

Page 5: ...ields inside the magnetic room have the potential to dislodge items at high velocities and can result in serious injury or death Caution For questions regarding installation procedures or technical support call Troyka Med Service team or contact via email at info troykamed com Caution Only system components explicitly designed for use inside the MRI suite should be placed inside the magnet room Co...

Page 6: ...ase consult your Troyka Med Sales or Service office Always use the power supply cord supplied in the original shipping carton If the enclosed power cord could not be used due to a different standard in your country use a power cord that conforms to the fallowing regional standards United States UL United Kingdom BASEC BS Germany VDE Switzerland SEV Canada CSA Japan MITI In other regions please use...

Page 7: ...or overview MRI room The T 280 MRI Dom Camera System is designed to be MRI conditional and is manufactured and tested to the highest standards The camera system is designed to be used with all MRI scanners up to 3 Tesla magnetic field strength A picture of MRI conditional dom camera is given in Figure 1 The camera can be used both on the wall or ceiling mount position and the angle of view could b...

Page 8: ...nic Parameter 1 25s 1 100 000s 25fps 1080p 30fps 1080P High speed long distance real time transmission Full HD and standard definition switch Day night ICR 3D DNR 3 4 Installation 3 4 1 Installation Diagram of MRI Video Camera in Magnet Room A representative drawing is showing the layout plan of the MRI video camera is given in Figure 2 The camera shown in Figure 2 1 depending on the customer requ...

Page 9: ...em will be ready to use In order to power on the camera turn on the power switch which is available on the interface unit Figure 2 9 Figure 2 MR conditional dome type video camera installation diagram 3 4 2 MRI Camera Installation diagram The representative drawing showing the installation diagram of the MRI camera is given in Figure 3 Use 4 screws delivered in the package to mount the base part o...

Page 10: ...g Unplug all power connections before cleaning 4 1 1 Monitor Surface Dampen do not saturate a clean lint free cloth with environmentally friendly glass cleaner The cleaner contains spirit as an active substance up to 98 and tensides which can be biologically recycled Cline the monitor screen using circular motions with the cloth to avoid streams Remove fingerprints grease dirt and dust Carefully d...

Reviews: