3-3. Function Instruction:
figure(7)
(1)
Automatic Current Cutback
(ACD):See
figure (7), as ACD dip switch OFF, Motor
stops current and from RUN current to STOP
current. No ACD function as ACD dip switch
ON.
Table(2) TR22H-D operating current
scale
current
scale
current
0
0.10A
8
1.16A
1
0.24A
9
1.30A
2
0.38A
A
1.42A
3
0.49A
B
1.55A
4
0.63A
C
1.69A
5
0.77A
D
1.82A
6
0.90A
E
1.93A
7
1.02A
F
2.06A
(2)Self Test(TEST):See figure (7), TEST dip
switch ON, driver sends a pulse signal every
second.
(3)Division Adjust (C/S):See figure (7),C/S is
switch of division adjust. Division as Table(1)
(4)RUN and STOP Current Adjust:See figure (7),
RUN、STOP is switch of current adjust。
Operating
current please refer to Table (2)、Table (3).
scale
current
scale
current
0
0.24A
8
2.34A
1
0.51A
9
2.61A
2
0.79A
A
2.84A
3
1.02A
B
3.11A
4
1.29A
C
3.38A
5
1.56A
D
3.65A
6
1.83A
E
3.90A
7
2.07A
F
4.18A
Table(3) TR24H-D operating current
scale
0
1
2
3
4
division
1
2
4
8
16
scale
5
6
7
8
9
division
32
64
128
256
256
Table (1)