Low-noise operation mode (MUTE)

In low-noise operation mode, the device works at the lowest
heating level. The fan rotates at minimum speed.
Start low-noise operation mode as follows:

1. Repeatedly press the button for the selection of the

operation mode (13) until the indicator light MUTE (12) is
illuminated.

Ionisation function (ION)

When activating the ionisation function, the ion generator
produces negatively charged ions. These ions charge the
oxygen molecules of the ambient air and bind suspended matter
and dust particles in the air. This way the ambient air is
cleaned, which improves human well-being.
Start the ionisation function as follows:

1. Press the button for the activation of the ion generator (16)

until the indicator light ION (9) is illuminated.

Switch-off timer

Use the switch-off timer to automatically switch off the device
after a specified time interval (1, 2, 4 or 8 hours).
Start the switch-off timer as follows:

1. Repeatedly press button 14 until one of the indicator

lights (11) is illuminated and thus indicates the set switch-
off time value in hours.

2. Press button 14 again to disable the switch-off timer.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Wait for approx. 2 minutes.

– Due to the follow-up time of the internal components,

the device only switches off completely after approx. 2
minutes.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Empty the condensation tank, if need be.

Clean the device according to the Maintenance chapter.

Store the device according to the Storage chapter.

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Check the condensation tank for correct seating.

Check the room temperature. Observe the device's
permissible operating range according to the technical
data.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is running, but there is no formation of
condensate:

Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.

Check the room temperature. Observe the device's
permissible operating range according to the technical
data.

Ensure that the relative room humidity complies with the
technical data.

Check the preselected desired humidity level. The humidity
in the room must be above the selected range. If required,
select another operation mode by use of button 13.

Check the air filter for dirt. If necessary, clean or replace
the air filter.

From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Condensate is leaking:

Check the device for leaks.

The device gets very warm, is loud or loses power:

Check the air inlets and air filter for dirt. Remove external
dirt.

From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.

Notice

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.

Notice

For reasons of safety, the device switches off
automatically after a period of 24 hours.

Summary of Contents for TTR 55 E

Page 1: ...TRT BA TTR55E TC 004 EN TTR 55 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...e Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in...

Page 3: ...nsure that the air inlet and outlet are not obstructed Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects Only transport the device in an upright po...

Page 4: ...ensation tank 2 with integrated overflow protection ensure fault free operation The fan sucks in damp room air via the air inlet 3 with air filter 1 the condenser and the desiccant wheel located behin...

Page 5: ...he condensation drain hose see chapter Maintenance After transporting the device observe the following Set up the device in an upright position after transport Leave the device to rest for one hour be...

Page 6: ...re that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies with the res...

Page 7: ...3 Select the desired operation mode by use of button 13 Info If the target humidity value is not reached within 24 hours the device switches off automatically regardless of the operating mode The devi...

Page 8: ...ot start Check the power connection Check the power cable and mains plug for damages Check the on site fusing Check the condensation tank for correct seating Check the room temperature Observe the dev...

Page 9: ...months at least annually Empty condensation tank and drain hose X Check the air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the in...

Page 10: ...terior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace air filter Check for damage Check the attachment scr...

Page 11: ...of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have t...

Page 12: ...ULL indication 8 will be illuminated The compressor and fan will switch off 1 Take the condensation tank out of the device 2 Remove the condensation tank cover 3 Empty the condensation tank over a dra...

Page 13: ...o longer work properly Any warranty claims will be voided in this case Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to th...

Page 14: ...lectronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com...

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: