![Trotec TTR 55 E Operating Manual Download Page 12](http://html1.mh-extra.com/html/trotec/ttr-55-e/ttr-55-e_operating-manual_1171879012.webp)
11
EN
Operating manual – dehumidifier TTR 55 E
4. Reinsert the air filter into the device.
Emptying the condensation tank
If the condensation tank is full or not installed correctly, the
FULL indication (8) will be illuminated. The compressor and fan
will switch off.
1. Take the condensation tank out of the device.
2. Remove the condensation tank cover.
3. Empty the condensation tank over a drain or sink.
4. Rinse the condensation tank with clear water. Regularly
clean the condensation tank using a mild cleaning agent
(no detergent!).
5. Fit the cover back on the condensation tank.