EN
6
Operating manual – dehumidifier TTR 55 E
Operation
•
After being switched on, the device operates fully
automatically until the float indicates that the condensation
tank is full and the device switches itself off.
•
Avoid open doors and windows.
Operating elements
FULL
POWER
ION
UPPER
BELOW
WIDE
1
2
4
8
AUTO
CONT
DRY
MUTE
POWER
ION
SWING
TIMER
SELECT
8
17
9
10
11
12
13
14
15
16
No.
Operating element
8
FULL:
Condensation tank indicator light; is illuminated when
the condensation tank is full.
POWER:
Is illuminated when the device is switched on.
9
ION:
Is illuminated when ionisation mode is activated.
10
WIDE:
Is illuminated when the air flap is fully pivoted from
bottom to top.
BELOW:
Is illuminated when the air flap is only pivoted in the
lower angle range.
UPPER:
Is illuminated when the air flap is only pivoted in the
upper angle range.
11
One of the indicators is illuminated when the switch-off
timer is activated by means of the TIMER button (1 = one
hour, 2 = two hours, 4 = four hours, 8 = eight hours).
12
The corresponding indicator light of the selected
operation mode is illuminated.
AUTO: Normal operation mode
CONT: Continuous operation
DRY: Eco mode
MUTE: Low-noise operation mode
13
Button to select the operation mode
14
Button to activate and set the switch-off timer
15
Button to adjust the position of the air flap
16
Button to activate the ionisation function
17
Power button; switches the device on or off.
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Press the Power button (17).
2. Check whether the condensation tank indicator light (8) is
out.
3. Select the desired operation mode by use of button 13.
Info
If the target humidity value is not reached within
24 hours, the device switches off automatically
regardless of the operating mode.
The device also switches off if the target value was
reached for a short time but the heating could not cool
down sufficiently. After reaching the target value, the
heating requires a certain time (approx. 6 min) to cool
down.
If the target value is reached within 24 hours and the
heating always has sufficient time to cool down, the
device will remain in operation even for weeks.
Normal operation mode (AUTO)
The device regulates the dehumidification performance
according to the room air's humidity level and the fan stage:
•
Above a humidity of 70 %, heater and fan work at the
highest level.
•
With a humidity level between 50 % and 70 % the heater
works in low stage and the fan in medium stage.
•
Below 50 % humidity, the heater is switched off and the
fan works at the lowest stage.
Start normal operation mode as follows:
1. Repeatedly press the button for the selection of the
operation mode (13) until the indicator light AUTO (12) is
illuminated.
Continuous operation mode (CONT)
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity. This special function
improves the clothes drying process by continuous operation of
the dehumidifier at full capacity.
Start the continuous operation mode as follows:
1. Repeatedly press the button for the selection of the
operation mode (13) until the indicator light CONT (12) is
illuminated.
Eco mode (DRY)
In eco mode, the device works at the lowest heating level. The
fan rotates at medium speed. Thus, the energy consumption is
reduced.
Start eco mode as follows:
1. Repeatedly press the button for the selection of the
operation mode (13) until the indicator light DRY (12) is
illuminated.