Operation

After being switched on, the device operates fully
automatically until the float indicates that the condensation
tank is full and the device switches itself off.

Avoid open doors and windows.

Operating elements

FULL

POWER

ION

UPPER

BELOW

WIDE

1

2

4

8

AUTO

CONT

DRY

MUTE

POWER

ION

SWING

TIMER

SELECT

8

17

9

10

11

12

13

14

15

16

No.

Operating element

8

FULL: 
Condensation tank indicator light; is illuminated when
the condensation tank is full.
POWER: 
Is illuminated when the device is switched on.

9

ION: 
Is illuminated when ionisation mode is activated.

10

WIDE: 
Is illuminated when the air flap is fully pivoted from
bottom to top.
BELOW: 
Is illuminated when the air flap is only pivoted in the
lower angle range.
UPPER: 
Is illuminated when the air flap is only pivoted in the
upper angle range.

11

One of the indicators is illuminated when the switch-off
timer is activated by means of the TIMER button (1 = one
hour, 2 = two hours, 4 = four hours, 8 = eight hours).

12

The corresponding indicator light of the selected
operation mode is illuminated.
AUTO: Normal operation mode
CONT: Continuous operation
DRY: Eco mode
MUTE: Low-noise operation mode

13

Button to select the operation mode

14

Button to activate and set the switch-off timer

15

Button to adjust the position of the air flap

16

Button to activate the ionisation function

17

Power button; switches the device on or off.

Switching the device on

Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.

1. Press the Power button (17).
2. Check whether the condensation tank indicator light (8) is

out.

3. Select the desired operation mode by use of button 13.

Info

If the target humidity value is not reached within
24 hours, the device switches off automatically
regardless of the operating mode.
The device also switches off if the target value was
reached for a short time but the heating could not cool
down sufficiently. After reaching the target value, the
heating requires a certain time (approx. 6 min) to cool
down.
If the target value is reached within 24 hours and the
heating always has sufficient time to cool down, the
device will remain in operation even for weeks.

Normal operation mode (AUTO)

The device regulates the dehumidification performance
according to the room air's humidity level and the fan stage:

Above a humidity of 70 %, heater and fan work at the
highest level.

With a humidity level between 50 % and 70 % the heater
works in low stage and the fan in medium stage.

Below 50 % humidity, the heater is switched off and the
fan works at the lowest stage.

Start normal operation mode as follows:

1. Repeatedly press the button for the selection of the

operation mode (13) until the indicator light AUTO (12) is
illuminated.

Continuous operation mode (CONT)

In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity. This special function
improves the clothes drying process by continuous operation of
the dehumidifier at full capacity.
Start the continuous operation mode as follows:

1. Repeatedly press the button for the selection of the

operation mode (13) until the indicator light CONT (12) is
illuminated.

Eco mode (DRY)

In eco mode, the device works at the lowest heating level. The
fan rotates at medium speed. Thus, the energy consumption is
reduced.
Start eco mode as follows:

1. Repeatedly press the button for the selection of the

operation mode (13) until the indicator light DRY (12) is
illuminated.

Summary of Contents for TTR 55 E

Page 1: ...TRT BA TTR55E TC 004 EN TTR 55 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...e Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in...

Page 3: ...nsure that the air inlet and outlet are not obstructed Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects Only transport the device in an upright po...

Page 4: ...ensation tank 2 with integrated overflow protection ensure fault free operation The fan sucks in damp room air via the air inlet 3 with air filter 1 the condenser and the desiccant wheel located behin...

Page 5: ...he condensation drain hose see chapter Maintenance After transporting the device observe the following Set up the device in an upright position after transport Leave the device to rest for one hour be...

Page 6: ...re that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies with the res...

Page 7: ...3 Select the desired operation mode by use of button 13 Info If the target humidity value is not reached within 24 hours the device switches off automatically regardless of the operating mode The devi...

Page 8: ...ot start Check the power connection Check the power cable and mains plug for damages Check the on site fusing Check the condensation tank for correct seating Check the room temperature Observe the dev...

Page 9: ...months at least annually Empty condensation tank and drain hose X Check the air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the in...

Page 10: ...terior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace air filter Check for damage Check the attachment scr...

Page 11: ...of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have t...

Page 12: ...ULL indication 8 will be illuminated The compressor and fan will switch off 1 Take the condensation tank out of the device 2 Remove the condensation tank cover 3 Empty the condensation tank over a dra...

Page 13: ...o longer work properly Any warranty claims will be voided in this case Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to th...

Page 14: ...lectronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com...

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: