11
EN
Operating manual – dehumidifier TTK 54 E / TTK 66 E
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error messages can be displayed in the segment
display (22):
Error code
Cause
Remedy
AS
Fault at humidity sensor
Disconnect the device briefly from
the mains.
Should the error still be displayed
after the restart, please contact
the customer service.
ES
Fault at temperature sensor
E3
General fault at the device
EC
Leaking refrigerant
Switch the device off and contact
the customer service.
P1
Automatic defrost
This is not a fault. Wait for a brief
period. The indication will
disappear the moment the
automatic defrost process is
completed.
P2
Condensation tank full or
not inserted correctly
Empty the condensation tank or
check the condensation tank for
correct fit.