background image

2

EN

dehumidifier TTK 53 E / TTK 72 E

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 4

Transport and storage........................................................... 6

Assembly and installation..................................................... 6

Operation ............................................................................... 8

Errors and faults.................................................................. 12

Maintenance ........................................................................ 13

Technical annex................................................................... 17

Disposal ............................................................................... 17

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

TTK 53 E

https://hub.trotec.com/?id=42189

TTK 72 E

https://hub.trotec.com/?id=41804

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

Summary of Contents for TTK 53 E

Page 1: ...TRT BA TTK53E TTK72E TC2016 09 004 EN TTK 53 E TTK 72 E EN OPERATING MANUAL DEHUMIDIFIER ...

Page 2: ...TK 53 E https hub trotec com id 42189 TTK 72 E https hub trotec com id 41804 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all war...

Page 3: ...chapter Make sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose Discharge the collected condensate b...

Page 4: ...he evaporator and to the condenser located behind it The air is cooled at the cold evaporator until it is below the dew point Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime The dehumidified cooled air is slightly warmed at the condenser and blown out again The drier air thus conditioned mixes with the air in the room The humidity in the room wher...

Page 5: ... 3 4 5 6 7 8 9 2 3 10 No Designation 1 Control panel 2 Transport handle 3 Wheels 4 Air inlet with air filter 5 Condensation drain hose connection 6 Condensation tank 7 Air filter 8 Condensation drain hose 9 Air outlet 10 Colour LED for current room humidity ...

Page 6: ...ank prior to storage Hold onto the mains plug while pulling the power cable out of the mains socket Drain any possibly remaining condensate When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Place no furt...

Page 7: ...air filter Note Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the air filter is installed before switching the device on Inserting the condensation tank Ensure that the float inside the condensation tank is inserted correctly En...

Page 8: ...o Designation Meaning 16 MODE button Selection button for operating modes Automatic mode Dehumidification additionally continuous operation Laundry drying function Ventilation 17 STAND BY button Power button Switches the device on or off 18 OPERATION indication Illuminated when the device is switched on 19 AUTOMATIC indication Automatic mode is active 20 CONTINUOUS indication Dehumidification mode...

Page 9: ...UTOMATIC indication 19 is illuminated Laundry drying function The device may be used to dry clothes in a more timely manner When positioning the device or a clothes horse please observe the minimum distances specified in the technical data The device dehumidifies the air constantly and regardless of the relative room humidity The fan runs at the highest speed The relative room humidity and the fan...

Page 10: ... Wait for approx 5 seconds in order to save the setting ð The TIMER indication 24 is illuminated ð The relative room humidity is indicated in the segment display 13 again ð The device switches off after the set period of time Memory function The device memorizes the last selected operating mode and in dehumidification mode 20 also the set room humidity during short power failures If the timer was ...

Page 11: ... vary Do not switch off the device during automatic defrost Do not remove the mains plug from the mains socket Drying laundry In addition the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces When positioning the device or a clothes horse please observe the minimum distances specified in the technical data For drying laundry the following values shou...

Page 12: ...the outside check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device might carry out an automatic defrost During automatic defrost the device does not dehumidify The device is loud or vibrates Check whether the device is set up in a stable and upright position Condensate is leaking Check the device for leaks The ...

Page 13: ...hs at least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter for dirt and foreign objects and clean or replace if necessary X X Replace the air filter X Check for damage X Check the attachment screws X X Test run X Empty the condensation tank and drain hose ...

Page 14: ...or dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Empty the condensation tank and drain hose Comments 1 Date Signature 2 Date Signature 3 Date Signature 4 Date Signature 5 Date Signature 6 Date Signature 7 Date Signature 8 Date Signature 9 Date Signature 10 Date Signature 11 Date ...

Page 15: ...e inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning ...

Page 16: ...tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on Activities required after maintenance If you want to continue using the device Leave the device to rest for 12 t...

Page 17: ... The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return option...

Page 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: