Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Check the filling level of the condensation tank and empty
it if necessary. The 

Tank Full

 indication (23) must not light

up.

Check the condensation tank for correct seating.

Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5 °C).

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is running, but there is no formation of
condensate:

Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.

Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5 °C).

Ensure that the relative room humidity complies with the
technical data.

Check the preselected relative room humidity. The
humidity in the room must be above the selected range.

Check the air filter for dirt. If necessary, clean or replace
the air filter.

From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.

The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Condensate is leaking:

Check the device for leaks.

The compressor does not start:

Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5 °C).

Ensure that the relative room humidity complies with the
technical data.

Check the preselected relative room humidity. The
humidity in the room must be above the selected range.

Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10 minutes before
reconnecting it.

The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.

The device gets very warm, is loud or loses power:

Check the air inlets and air filters for dirt. Remove external
dirt.

From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.

Summary of Contents for TTK 53 E

Page 1: ...TRT BA TTK53E TTK72E TC2016 09 004 EN TTK 53 E TTK 72 E EN OPERATING MANUAL DEHUMIDIFIER ...

Page 2: ...TK 53 E https hub trotec com id 42189 TTK 72 E https hub trotec com id 41804 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all war...

Page 3: ...chapter Make sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose Discharge the collected condensate b...

Page 4: ...he evaporator and to the condenser located behind it The air is cooled at the cold evaporator until it is below the dew point Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime The dehumidified cooled air is slightly warmed at the condenser and blown out again The drier air thus conditioned mixes with the air in the room The humidity in the room wher...

Page 5: ... 3 4 5 6 7 8 9 2 3 10 No Designation 1 Control panel 2 Transport handle 3 Wheels 4 Air inlet with air filter 5 Condensation drain hose connection 6 Condensation tank 7 Air filter 8 Condensation drain hose 9 Air outlet 10 Colour LED for current room humidity ...

Page 6: ...ank prior to storage Hold onto the mains plug while pulling the power cable out of the mains socket Drain any possibly remaining condensate When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Place no furt...

Page 7: ...air filter Note Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the air filter is installed before switching the device on Inserting the condensation tank Ensure that the float inside the condensation tank is inserted correctly En...

Page 8: ...o Designation Meaning 16 MODE button Selection button for operating modes Automatic mode Dehumidification additionally continuous operation Laundry drying function Ventilation 17 STAND BY button Power button Switches the device on or off 18 OPERATION indication Illuminated when the device is switched on 19 AUTOMATIC indication Automatic mode is active 20 CONTINUOUS indication Dehumidification mode...

Page 9: ...UTOMATIC indication 19 is illuminated Laundry drying function The device may be used to dry clothes in a more timely manner When positioning the device or a clothes horse please observe the minimum distances specified in the technical data The device dehumidifies the air constantly and regardless of the relative room humidity The fan runs at the highest speed The relative room humidity and the fan...

Page 10: ... Wait for approx 5 seconds in order to save the setting ð The TIMER indication 24 is illuminated ð The relative room humidity is indicated in the segment display 13 again ð The device switches off after the set period of time Memory function The device memorizes the last selected operating mode and in dehumidification mode 20 also the set room humidity during short power failures If the timer was ...

Page 11: ... vary Do not switch off the device during automatic defrost Do not remove the mains plug from the mains socket Drying laundry In addition the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces When positioning the device or a clothes horse please observe the minimum distances specified in the technical data For drying laundry the following values shou...

Page 12: ...the outside check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device might carry out an automatic defrost During automatic defrost the device does not dehumidify The device is loud or vibrates Check whether the device is set up in a stable and upright position Condensate is leaking Check the device for leaks The ...

Page 13: ...hs at least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter for dirt and foreign objects and clean or replace if necessary X X Replace the air filter X Check for damage X Check the attachment screws X X Test run X Empty the condensation tank and drain hose ...

Page 14: ...or dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Empty the condensation tank and drain hose Comments 1 Date Signature 2 Date Signature 3 Date Signature 4 Date Signature 5 Date Signature 6 Date Signature 7 Date Signature 8 Date Signature 9 Date Signature 10 Date Signature 11 Date ...

Page 15: ...e inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning ...

Page 16: ...tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on Activities required after maintenance If you want to continue using the device Leave the device to rest for 12 t...

Page 17: ... The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return option...

Page 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: