16
EN
dehumidifier TTK 33 E
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned
correctly.
In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
Activities required after maintenance
If you want to continue using the device:
•
Leave the device to rest for 12 to 24 hours, so the
refrigerant can accumulate within the compressor.
Wait 12 to 24 hours before switching the device back on!
Acting contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Transport and storage
chapter.
Technical annex
Technical data
Parameter
Value
Model
TTK 33 E
Dehumidifying capacity, max.
14 l / 24 h
Dehumidification performance
@ 30 °C and 80 % RH
12 l / 24 h
Air volume
80 m
3
/h
Operating range (temperature) 5 °C to 32 °C
Operating range (relative
humidity)
30 % to 80 % RH
Pressure suction side
0.8 MPa
Pressure outlet side
2.8 MPa
Max. permissible pressure
3.8 MPa
Mains connection
220-240 V / 50 Hz
Max. power input
240 W
Nominal current
1.3 A
Refrigerant
R290
Amount of refrigerant
52 g
GWP factor
3
CO
2
equivalent
0.000156 t
Water tank
1.5 l
Sound pressure level
43 dB(A)
Dimensions (length x width x
height)
205 x 270 x 420 mm
Minimum distance to walls and
other objects
A: top
B: rear
C: side
D: front
50 cm
20 cm
20 cm
20 cm
Weight
10 kg