Trotec TTK 125 S Original Instructions Manual Download Page 9

EN

9

dehumidifier TTK 125 S

3.

1/2''

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Empty the condensation tank, if need be.

Clean the device according to the Maintenance chapter.

Store the device according to the Storage chapter.

Available accessories

Warning

Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.

Designation

Article number

Air filter TTK 125 S (filter fleece)

7.160.000.006

External condensate pump

6.100.003.030

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Check the filling level of the condensation tank and empty
it if necessary. The 

Condensation tank

 LED (14) must not

light up.

Check the room temperature. Observe the device's
permissible operating range according to the technical
data.

The device is running, but there is no formation of
condensate:

Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.

Check the room temperature. Observe the device's
permissible operating range according to the technical
data.

Ensure that the relative room humidity complies with the
technical data.

Check the air filter for dirt. If necessary, clean or replace
the air filter.

From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.

The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Condensate is leaking:

Check the device for leaks.

Summary of Contents for TTK 125 S

Page 1: ...TRT BA TTK125S TC2018 54 004 EN TTK 125 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...l instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be use...

Page 3: ...chives laboratories garages bathrooms wash rooms changing rooms etc Improper use Do not place the device on wet or flooded ground Do not place any objects e g clothing on the device Do not use the dev...

Page 4: ...ly the device may be damaged Note the information regarding transport and storage of the device Transport To make the device easier to transport it is fitted with wheels Before transporting the device...

Page 5: ...sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residua...

Page 6: ...6 EN dehumidifier TTK 125 S 1 2 3 4 5...

Page 7: ...4 Condensation tank LED Is displayed when the condensation tank is full or not installed correctly 15 Status LED Indicates the operating status and error messages The device is optionally available wi...

Page 8: ...defrost Do not remove the mains plug from the mains socket Temperature limitation overheating protection The device comes with a temperature limitation It serves to protect e g the compressor from ov...

Page 9: ...he power cable and mains plug for damages Check the on site fusing Check the filling level of the condensation tank and empty it if necessary The Condensation tank LED 14 must not light up Check the r...

Page 10: ...and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks...

Page 11: ...and drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and c...

Page 12: ...dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit Th...

Page 13: ...of the selection switch the compressor will only switch back on after a delay The fan keeps running independently of the compressor The fan only switches off if the condensation tank is removed 1 OFF...

Page 14: ...side 4 2 MPa Air volume flow 300 m h Mains connection 1 N PE 230 V 50 Hz Power consumption max 0 6 kW Nominal current 2 6 A Water tank capacity 6 l Refrigerant R 407C Amount of refrigerant 530 g GWP f...

Page 15: ...Wasserpumpe Stockdose e c n e s e r P k n a T Tank Full Mikroschalter Wippe Vo lstand Beh lter voll l l o v r e t l h e B l l u f k n a T Standard Standard Tank Pr senz Zeit Z hler E N S1 S2 S3 S4 L M...

Page 16: ...ator Time Energy Counter Water Pump Socket Wasserpumpe Stockdose e c n e s e r P k n a T Tank Full Mikroschalter Wippe Vo lstand Beh lter voll Tank Presence Z l a n o i t p O Tank Pr senz Tank Pr senz...

Page 17: ...EN 17 dehumidifier TTK 125 S Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual...

Page 18: ...nning Castor D3 Aluminium Evaporating Coil Capillary Tube Filter Drier A10 Protection Box PCB Support B10 EPS Top Plate D4 R407c Solenoid Valve A11 Protection Box Left Support B11 ABS Piece for Spring...

Page 19: ...e national regulations Declaration of conformity The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 3971...

Page 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: