dehumidifier TTK 125 S
6.
7.
Connecting the power cable
•
Insert the mains plug into a properly secured mains
socket.
Operation
Control panel
OFF
X
SSTTAATTU
USS
TANK
FULL
OFF
X
SSTTAATTU
USS
TANK
FULL
11
12
13
14
10
15
No. Designation
Meaning
10 Operating hours
counter
Indication of operating hours
11 Kilowatt hours
counter, MID-
certified (optional)
Indication of energy consumption
12 Rotary switch
Selection of relative room humidity
13 Mains switch
Switching the device on and off;
Is illuminated when the device is
switched on
14
Condensation tank
LED
Is displayed when the condensation
tank is full or not installed correctly
15
Status
LED
Indicates the operating status and
error messages
The device is optionally available with an operating element with
dual counter (see the image at the top right). The dual counter
registers both the operating hours and the energy consumption
and is certified according to the MID (Measuring Instruments
Directive 2004/22/EC). The kWh display is factory-calibrated
and may be used for accounting purposes. Contact your Trotec
customer service.
The
Status
LED (15) flashes once a second during normal
operation. If it flashes more frequently, lights up permanently or
does not light up at all, there might be a fault, see chapter
Errors and faults.