Trotec TTK 125 S Original Instructions Manual Download Page 2

2

EN

dehumidifier TTK 125 S

Table of contents

Notes regarding the instructions .......................................... 2

Safety ..................................................................................... 2

Information about the device................................................ 4

Transport and storage........................................................... 4

Assembly and installation..................................................... 5

Operation ............................................................................... 7

Available accessories............................................................ 9

Errors and faults.................................................................... 9

Maintenance ........................................................................ 11

Technical annex................................................................... 14

Disposal ............................................................................... 19

Declaration of conformity ................................................... 19

Notes regarding the instructions

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
instructions must be observed.

You can download the current version of the instructions and
the EU declaration of conformity via the following link:

TTK 125 S

https://hub.trotec.com/?id=39716

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Summary of Contents for TTK 125 S

Page 1: ...TRT BA TTK125S TC2018 54 004 EN TTK 125 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...l instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be use...

Page 3: ...chives laboratories garages bathrooms wash rooms changing rooms etc Improper use Do not place the device on wet or flooded ground Do not place any objects e g clothing on the device Do not use the dev...

Page 4: ...ly the device may be damaged Note the information regarding transport and storage of the device Transport To make the device easier to transport it is fitted with wheels Before transporting the device...

Page 5: ...sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residua...

Page 6: ...6 EN dehumidifier TTK 125 S 1 2 3 4 5...

Page 7: ...4 Condensation tank LED Is displayed when the condensation tank is full or not installed correctly 15 Status LED Indicates the operating status and error messages The device is optionally available wi...

Page 8: ...defrost Do not remove the mains plug from the mains socket Temperature limitation overheating protection The device comes with a temperature limitation It serves to protect e g the compressor from ov...

Page 9: ...he power cable and mains plug for damages Check the on site fusing Check the filling level of the condensation tank and empty it if necessary The Condensation tank LED 14 must not light up Check the r...

Page 10: ...and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks...

Page 11: ...and drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and c...

Page 12: ...dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit Th...

Page 13: ...of the selection switch the compressor will only switch back on after a delay The fan keeps running independently of the compressor The fan only switches off if the condensation tank is removed 1 OFF...

Page 14: ...side 4 2 MPa Air volume flow 300 m h Mains connection 1 N PE 230 V 50 Hz Power consumption max 0 6 kW Nominal current 2 6 A Water tank capacity 6 l Refrigerant R 407C Amount of refrigerant 530 g GWP f...

Page 15: ...Wasserpumpe Stockdose e c n e s e r P k n a T Tank Full Mikroschalter Wippe Vo lstand Beh lter voll l l o v r e t l h e B l l u f k n a T Standard Standard Tank Pr senz Zeit Z hler E N S1 S2 S3 S4 L M...

Page 16: ...ator Time Energy Counter Water Pump Socket Wasserpumpe Stockdose e c n e s e r P k n a T Tank Full Mikroschalter Wippe Vo lstand Beh lter voll Tank Presence Z l a n o i t p O Tank Pr senz Tank Pr senz...

Page 17: ...EN 17 dehumidifier TTK 125 S Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual...

Page 18: ...nning Castor D3 Aluminium Evaporating Coil Capillary Tube Filter Drier A10 Protection Box PCB Support B10 EPS Top Plate D4 R407c Solenoid Valve A11 Protection Box Left Support B11 ABS Piece for Spring...

Page 19: ...e national regulations Declaration of conformity The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 3971...

Page 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...