7
EN
Operating manual – radial fan TFV PRO 1
Available accessories
Warning!
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Accessories
Article number
Adapter plate 3 x 100 mm,
with sealing caps
6.100.005.069
Adapter plate 8 x 50 mm,
with sealing caps
6.100.005.070
Adapter plate 12 x 38 mm,
with sealing caps
6.100.005.071
Sealing cap set 12 x 38 mm
7.310.000.301
Sealing cap set 8 x 50 mm
7.310.000.302
Sealing cap set 3 x 100 mm
7.310.000.303
38 mm hose Tronect PV-A
6.100.001.010
50 mm hose Tronect PV-A
6.100.001.020
100 mm hose Tronect TF-L
6.100.001.115
Air filter
7.160.000.008
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The fan is not running:
•
Check whether the unit is switched on.
•
Check the power supply.
•
Check the cable and power plug for defects.
The fan operates only for a short time, then switches off
automatically:
•
Check the air inlet for dirt. Clean it if required.
•
The motor bearing or cable connections might be
defective. If so, contact Trotec or a specialist electrical
company.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
The motor or fan is noisy or runs unevenly:
•
The fan is soiled. Clean the fan according to the
Maintenance chapter.
•
The fan is damaged. If so, contact Trotec or a specialist
electrical company.
•
The motor bearing might be damaged. If so, contact Trotec
or a specialist electrical company.
The fan produces grinding noises:
•
The fan blades are dirty or foreign objects are located in
the rotation range of the fan. Clean the fan blades
according to the Maintenance chapter.
•
The fan blades might be damaged. If so, contact Trotec or
a specialist electrical company.
The device vibrates heavily:
•
Check the floor space of the fan. Position the device on a
level and firm surface.
•
There might be an imbalance in the fan blades. If so,
contact Trotec or a specialist electrical company.
The air flow rate is low:
•
Check the air inlet for dirt. Clean it if required.
•
Check whether the hose connectors which are not needed
are fitted with a sealing cap. Close hose connectors which
are not used with a sealing cap if necessary.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.