background image

EN

2

Operating manual – radial fan TFV PRO 1

Warranty and liability

The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be
remedied with the measures in the chapter Errors and faults,
please get in touch with your dealer or distributor.
When making a warranty claim, supply the serial number (see
nameplate).
When manufacturer's instructions or legal regulations have not
been followed, or after unauthorised changes to the device are
made, the manufacturer is not responsible for the resulting
damages. Changes to the device or unauthorised replacement
of individual parts can drastically impact the electrical safety of
this product and will result in the loss of the warranty. Liability
does not extend to damages to people or property caused by the
device being used other than as described in the instructions in
this operating manual. Subject to changes to technical design
and model changes as part of constant development and
product improvement without prior notice.
No liability is accepted for damages resulting from improper
use. In such a case, any warranty claims will be voided also.

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
Defective power cables pose a serious health risk.

Observe the storage and operating conditions (see chapter
Technical data).

Ensure that the air inlet and outlet are not obstructed.

Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.

Intended use

Use the device for ventilation, air circulation or air transport
whilst adhering to the technical data and the safety instructions.
The device was designed for the generation of a powerful,
large-volume air circulation, e.g. for the accelerated drying of
buildings and rooms. The device can be operated in
combination with different accessories.
The device may be used for drying carpets, buildings or screed
as well as for the ventilation of poorly accessible intermediate
spaces.

Improper use

The device is not suited for installation in fluids or on flooded or
boggy grounds.
Any unauthorised changes, modifications or alterations to the
device are forbidden.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when using high-
performance fans.

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the operating manual, especially
the Safety chapter.

Summary of Contents for TFV PRO 1

Page 1: ...TRT BA TFVPRO1 TC 002 EN TFV PRO 1 EN OPERATING MANUAL RADIAL FAN ...

Page 2: ...n marked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed The current version of the operating manual can be found at TFV PRO 1 http hub trotec com id 39587 Legal notice This release replaces all previous versions No part of this publication may be reproduced without writ...

Page 3: ... accessories and connection parts for possible damage prior to every use of the device Do not use any defective devices or device parts Ensure that all electric cables outside of the device are protected from damage e g caused by animals Never use the device if electric cables or the power connection are damaged The electrical connection must correspond to the specifications in chapter Technical d...

Page 4: ...ce and result in damage to the device Note Do not use abrasive cleaners or solvents to clean the device Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect it from the mains 2 Remove persons from the danger area 3 Do not reconnect a defective device to the mains Information about the device Device description Th...

Page 5: ... from invasive dust if necessary stackable up to 5 devices on top of one another Assembly and installation Scope of delivery Device Air filter Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up Place the dev...

Page 6: ... and result in damage to the device Make sure that the air filter is installed before switching the device on The air filter must be seated in the lower guide rail Mounting an adapter plate optional You can mount optionally available adapter plates for 3 8 or 12 hose connectors to the device The adapter plate for 3 connectors is used as an example in the following The adapter plates with 8 or 12 c...

Page 7: ...ins plug into a properly secured mains socket Operation Operating elements h kWh 21 20 22 23 No Designation 20 Fan speed rotary control 21 Power button 22 Kilowatt hours counter with LED 23 Operating hours counter Switching the device on 1 Press the power button 21 ð The power button 21 lights up 2 Turn the rotary control 20 to the right until the fan starts running Info You can read the number of...

Page 8: ... defective If so contact Trotec or a specialist electrical company Check the air filter for dirt If necessary clean or replace the air filter The motor or fan is noisy or runs unevenly The fan is soiled Clean the fan according to the Maintenance chapter The fan is damaged If so contact Trotec or a specialist electrical company The motor bearing might be damaged If so contact Trotec or a specialist...

Page 9: ...ing by loosening the attachment screws 2 Clean the inside of the housing and the fan blades carefully with a slightly damp cloth 3 Allow the fan to dry 4 Reattach the upper cover to the housing Make sure that the cover is positioned correctly and that the seals fit exactly and are not damaged 5 Screw the upper cover to the housing again Cleaning the air filter The air filter should be cleaned prio...

Page 10: ... S1 2 1 L 5 4 N 10K R1 h kWh P1 LinLout N M1 DC out E1 GND L1 N PE Aderfarben wire colors sw schwarz black rt rot red ge gelb yellow gnge gruen gelb green yellow Gehäuse housing 230V AC 50 60Hz HW66 Kombizähler L in L out N BL GE RT SW BL GNGE bl blau blue Disposal In the European Union electronic equipment must not be treated as domestic waste but must be disposed of professionally in accordance ...

Page 11: ... of improper use installation maintenance etc or unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version Radial fan Series Year of manufacture as of 06 2016 Applicable regulations Applied harmonised standards Producer and authorised representative of the technical documentation Trotec GmbH Co KG Machinery Directive Low Voltage Directive ...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: