fan heater TFC 25 E
Overheating protection
The device is provided with a safety thermostat which is
activated by overheating of the device (when exceeding the
operating temperature).
Once the safety thermostat has switched itself on, the device
will be turned off.
When the device has cooled down sufficiently, it has to be
switched back on manually.
Investigate the cause of overheating.
If the safety thermostat does not switch in the event of
overheating, the overheating protection will be tripped. In that
case the device switches off completely. If so, please contact
the customer service to have the overheating protection
replaced.
Tilt protection
The device comes equipped with a tilt protection sensor. The tilt
protection is a safety device intended to minimize the risk of fire
in case the device is tipped over inadvertently. The device will
be switched off when knocked over (or if its upright position is
changed in any other manner).
The tilt protection switches the device off when it is inclined by
a few degrees out of its vertical position. The tilt protection is
also tripped when lifting the device a little, e.g. for transport
during operation. The device can again be used as usual only a
few seconds after placing it back in vertical position and on
solid ground.
Information about the device
Device description
The ceramic heater serves to generate and distribute warm air,
e.g. in interior spaces.
The device generates heat by means of a ceramic heating
element. The surrounding air is sucked in and heated in the
interior of the heating device. The heated air is blown into the
room by a fan.
The device is equipped with an integrated thermostat and so
generates a constant flow of warm air. In addition, you can set a
desired target temperature (5 °C to 35 °C) at the device.
Moreover, the device comes with an on-demand 80° oscillation
for an even better distribution of the warm air in the room.
Furthermore, the device is equipped with overheating protection
and tilt protection.
In order to dissipate the accumulated heat, the fan keeps
running for approx. 10 seconds after the heater's switch-off and
then switches off automatically.