pressure switch TDS DSP

– The pump operates continuously or frequently switches

on or off.

– The LEDs 

Power

 (5), 

Failure

 (6) and 

On

 (7) are

illuminated (green / yellow / orange).

– Turn pressure setting screw 2.5 times towards the

minus sign.

– The pressure is reduced by approx. 0.5 bar.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

If you like to disconnect the pressure switch from the water
network, (e.g. for cleaning, maintenance or storing during
winter), proceed as follows:

1. Disconnect the pressure switch from the power supply by

plugging the mains plug out of the mains socket.

2. Afterwards, disconnect the power supply of the pump from

the pressure switch.

3. Open a tap that is connected to the pressure switch to

release any remaining water pressure.

4. Disconnect the connection on the water outlet of the

pressure switch. Afterwards, disconnect the connection on
the water inlet of the pressure switch.

5. Empty the pressure switch (and your pump as well).

Carefully dry pressure switch and power cable.

Note

During winter, store pressure switch (and your pump)
in a dry room and protected against frost.

Errors and faults

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The connected pump does not start operating:

Check the power connection.

Check the power cable and mains plug for damage.

Check the on-site fusing.

Check the necessary initial pressure of the pump.

Check whether enough water is available and make sure
the water can be sucked by the pump without any
problems.

Check whether the LED 

Failure

 (6) is illuminated. If so,

press the 

Reset

 (4) button. If the pump is still not starting

to operate, make sure that the water in the water lines can
flow freely. If necessary, fill the pump with water (dry run).
If this does not help, check the pump for its correct
function and check whether the pump capacity is sufficient
(see Start-up chapter).

Check whether the power supply of the pump is switched
on. The LED 

On

 (7) on the pressure switch should be

illuminated.

The pump runs permanently and does not stop operating

Possible leakage in the system that exceeds the minimal
water flow rate of 1.2 l at which the pressure switch
switches off the pump. Check the distribution network for
leakages and remove any existing leakages.

The connected pump starts to operate several times and
stops again

Check the water line for leakages and remove any existing
leakages.

The pump runs permanently and does not stop operating

Possible leakage in the system that exceeds the minimal
water flow rate of 2 l at which the pressure switch
switches off the pump. Check the distribution network for
leakages and remove any existing leakages.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Notes on maintenance

Inside the device, there are no parts that need to be maintained
or lubricated by the user.

Cleaning

Clean the device with a soft, damp and lint-free cloth.
Protect electrical components from moisture. Do not use
any aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.

Summary of Contents for TDS DSP

Page 1: ...TRT BA TDPDSP TC2019 61 002 EN TDS DSP EN OPERATING MANUAL PRESSURE SWITCH...

Page 2: ...44132 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all...

Page 3: ...he cable for damage The use of extension cables which are not approved for outdoor use can result in injuries due to electric shock Before performing any work on the device in case of leaks in the wat...

Page 4: ...ust be able to read and understand electric circuit diagrams to put electrical systems into service and to maintain them to wire control cabinets to ensure the functionality of electrical components a...

Page 5: ...ed pump The restart button on the pressure switch is used for restarting the connected pump manually e g when the device switches the pump off because the pump is running dry In addition the device is...

Page 6: ...tion is protected from weather exposure and wet conditions Required pump pressure The required operating pressure of the pump to be connected depends on the height difference between pump and highest...

Page 7: ...t with the consumer side The device comes with 1 external thread The diameter of the connected lines may not be smaller 4 If the device is not equipped with a mains plug have the power cable for the p...

Page 8: ...m value the pressure switch switches off the pump for reasons of safety The LED Failure 6 is illuminated Please proceed as follows to restart the pressure switch and the pump 1 Stop the pump running d...

Page 9: ...be sucked by the pump without any problems Check whether the LED Failure 6 is illuminated If so press the Reset 4 button If the pump is still not starting to operate make sure that the water in the wa...

Page 10: ...ump connection without mains plug 3 phase A switching device must be interposed when three phase pumps are used The chosen capacity for the protection has to be compatible with the pump Disposal The i...

Page 11: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: