General safety warnings – Electrical safety

The device is to be supplied with a rated residual current
of no more than 30 mA by means of an RCD (Residual
Current protective Device).

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

Should the connection line of the device be damaged, it
must be replaced by the manufacturer, his customer
service or similarly qualified personnel in order to avoid
hazards.

Should there be a risk of flooding, install the plug
connections in a flood-proof area. 

There is a risk of

electric shock!

Make sure that the mains voltage corresponds to the
specifications on the nameplate.

Have all electrical installations carried out by an expert
according to the national regulations and the device-
specific requirements.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Protect the power supply cable against heat, oil and sharp
edges. Make sure that the power supply cable is not
crushed, kinked or subjected to other mechanical stresses.

Only use splash-proof extension cables intended for
outdoor use whilst observing the device's power input.
Before using cable drums, always unroll the cable
completely. Check the cable for damage. The use of
extension cables which are not approved for outdoor use
can result in injuries due to electric shock.

Before performing any work on the device, in case of leaks
in the water system, before taking work breaks or when
not in use, remove the mains plug from the mains socket.

General safety warnings – Personal safety

Never insert any objects or limbs into the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Warning
Device-specific safety warnings for pressure
switches

Before taking the device into operation, have the following
checked by an expert:

– Earthing, neutral conductor and RCD must be

functioning properly and correspond to the national
regulations,

– electrical plug connections must be protected from

moisture.

Provide appropriate frost protection.

Never operate the device in the rain. Keep the device away
from environmental influences such as wet conditions or
frost. In particular, keep the electrical connections dry and
make sure they are located in a flood-proof area.

Do not use the device at freezing temperatures or
temperatures above 60 °C.

Do not use the device for drinking water supply, and do not
integrate it into the drinking water circuit. In addition,
please observe the local regulations of the water and
wastewater authorities.

Intended use

The device serves for switching a connected garden or deep
well pump on and off. It is used to pump rainwater or service
water into private areas (e.g. into the garden) in compliance
with the regulations specified in the technical data. It is installed
in the water line between a pump and one or more extraction
points. From there, it activates or deactivates the connected
pump depending on the present water pressure and the flow
rate volume.
Clean fresh water is permitted as pump water (e.g. rainwater
from a cistern or ground water from a private well). The
temperature of the pumped water must not exceed 60° C.

Summary of Contents for TDS DSP

Page 1: ...TRT BA TDPDSP TC2019 61 002 EN TDS DSP EN OPERATING MANUAL PRESSURE SWITCH...

Page 2: ...44132 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all...

Page 3: ...he cable for damage The use of extension cables which are not approved for outdoor use can result in injuries due to electric shock Before performing any work on the device in case of leaks in the wat...

Page 4: ...ust be able to read and understand electric circuit diagrams to put electrical systems into service and to maintain them to wire control cabinets to ensure the functionality of electrical components a...

Page 5: ...ed pump The restart button on the pressure switch is used for restarting the connected pump manually e g when the device switches the pump off because the pump is running dry In addition the device is...

Page 6: ...tion is protected from weather exposure and wet conditions Required pump pressure The required operating pressure of the pump to be connected depends on the height difference between pump and highest...

Page 7: ...t with the consumer side The device comes with 1 external thread The diameter of the connected lines may not be smaller 4 If the device is not equipped with a mains plug have the power cable for the p...

Page 8: ...m value the pressure switch switches off the pump for reasons of safety The LED Failure 6 is illuminated Please proceed as follows to restart the pressure switch and the pump 1 Stop the pump running d...

Page 9: ...be sucked by the pump without any problems Check whether the LED Failure 6 is illuminated If so press the Reset 4 button If the pump is still not starting to operate make sure that the water in the wa...

Page 10: ...ump connection without mains plug 3 phase A switching device must be interposed when three phase pumps are used The chosen capacity for the protection has to be compatible with the pump Disposal The i...

Page 11: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...