ceramic heater TDS 30 M / TDS 50 M
Warning
Improper installation entails a risk of fire.
Do not place the device on combustible ground.
Do not place the device on high-pile carpets.
Do not use the device without the feet attached.
Warning
In order to avoid overheating and fire hazards, the
device must not be covered!
Behaviour in the event of an emergency
1. Switch the device off.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Overheating protection
The device is provided with a safety thermostat which is
activated by overheating of the device (when exceeding the
operating temperature).
Once the safety thermostat has switched itself on, the heating
will be turned off. The fan keeps running.
When the device has cooled down sufficiently, the heating will
be switched back on.
Investigate the cause of overheating.
If the safety thermostat does not switch in the event of
overheating, the overheating protection will be tripped. In that
case the device switches off completely. If so, please contact
the customer service to have the overheating protection
replaced.
Information about the device
Device description
The ceramic heater serves to generate and distribute warm air,
e.g. in interior spaces.
The device generates heat by means of a ceramic heating
element. The air surrounding the ceramic heating element is
heated. The heated air is blown into the room by a fan.
The device comes with an integrated thermostat and so
generates a constant flow of warm air.
Fan operation without heating function is also possible.
The device TDS 50 M is additionally equipped with a rundown
control for the fan after switch-off of the device.
Device depiction
1
3
4
5
6
2
TDS 30 M / TDS 50 M
No.
Designation
1
transport handle
2
air outlet
3
rotary switch room thermostat
4
selection switch ventilation and heating levels
5
operating light
6
air inlet