ceramic heater TDS 30 M / TDS 50 M

Warning

Improper installation entails a risk of fire.
Do not place the device on combustible ground.
Do not place the device on high-pile carpets.
Do not use the device without the feet attached.

Warning

In order to avoid overheating and fire hazards, the
device must not be covered!

Behaviour in the event of an emergency

1. Switch the device off.
2. In an emergency, disconnect the device from the mains

feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.

3. Do not reconnect a defective device to the mains.

Overheating protection

The device is provided with a safety thermostat which is
activated by overheating of the device (when exceeding the
operating temperature).
Once the safety thermostat has switched itself on, the heating
will be turned off. The fan keeps running.
When the device has cooled down sufficiently, the heating will
be switched back on.
Investigate the cause of overheating.
If the safety thermostat does not switch in the event of
overheating, the overheating protection will be tripped. In that
case the device switches off completely. If so, please contact
the customer service to have the overheating protection
replaced.

Information about the device

Device description

The ceramic heater serves to generate and distribute warm air,
e.g. in interior spaces.
The device generates heat by means of a ceramic heating
element. The air surrounding the ceramic heating element is
heated. The heated air is blown into the room by a fan.
The device comes with an integrated thermostat and so
generates a constant flow of warm air.
Fan operation without heating function is also possible.
The device TDS 50 M is additionally equipped with a rundown
control for the fan after switch-off of the device.

Device depiction

1

3

4
5

6

2

TDS 30 M / TDS 50 M

No.

Designation

1

transport handle

2

air outlet

3

rotary switch room thermostat

4

selection switch ventilation and heating levels

5

operating light

6

air inlet

Summary of Contents for TDS 10 M

Page 1: ...TRT BA TDS30M TDS50M TC2017 29 007 EN TDS 30 M TDS 50 M EN ORIGINAL INSTRUCTIONS CERAMIC HEATER ...

Page 2: ...ing link TDS 30 M https hub trotec com id 41085 TDS 50 M https hub trotec com id 41086 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Sa...

Page 3: ...repair work on the device remove the mains plug from the mains socket Hold onto the mains plug while doing so Switch the device off and disconnect the power cable from the mains socket when the device is not in use Do not under any circumstances use the device if you detect damages on the mains plug or power cable If the power cable is damaged it must be replaced by the manufacturer its service ag...

Page 4: ... by specialist electrical companies or by Trotec Symbols on the device Symbols Meaning This symbol located on the device indicates that it is prohibited to place objects such as towels clothes etc above or directly in front of the device In order to avoid overheating and fire hazards the heater must not be covered Residual risks Warning of electrical voltage Work on the electrical components must ...

Page 5: ...e heating will be switched back on Investigate the cause of overheating If the safety thermostat does not switch in the event of overheating the overheating protection will be tripped In that case the device switches off completely If so please contact the customer service to have the overheating protection replaced Information about the device Device description The ceramic heater serves to gener...

Page 6: ...an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Place no further devices or objects on top of the device to prevent it from being damaged Assembly and start up Scope of delivery 1 x Device 1 x Transport handle TDS 50 M only 2 x Screw TDS 50 M only 2 x Washer TDS 50 M only 1 x Manual Unpacking the device 1 Open the c...

Page 7: ... cable along the front of the device Operation The procedure is identical for the devices TDS 30 M TDS 50 M Avoid open doors and windows Control panel 4 3 No Designation 3 rotary switch room thermostat 4 selection switch ventilation and heating levels 0 OFF cold air ventilation heating level 1 heating level 2 Switching the device on Once you have completely installed the device as described in the...

Page 8: ...e device according to the following list The device does not start Check the power connection Check the power cable and mains plug for damages Check the on site fusing Check the room temperature The room thermostat may have switched off because the desired room temperature has been reached The motor might be defective Have a defective motor replaced by a specialist electrical company The room ther...

Page 9: ...rding to the technical data The device is loud or vibrates Check whether the device is set up in a stable and upright position Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on The device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorised specialist electrical co...

Page 10: ...rews X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Check air inlet grid s for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check for damage Check attachment sc...

Page 11: ... use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe the housing dry after cleaning Technical annex Technical data Parameter Value Model TDS 30 M TDS 50 M Heating capacity level 1 level 2 level 3 50 W 3300 W 5000 W 80 W 6000 W 9000 W Air flow rate 575 m h 1180 m h Operating range 15 C to 30 C 15 C to 30 C Mains connection ...

Page 12: ...12 EN ceramic heater TDS 30 M TDS 50 M Circuit diagram TDS 30 M ...

Page 13: ...EN 13 ceramic heater TDS 30 M TDS 50 M Circuit diagram TDS 50 M ...

Page 14: ... 30 GF 1 5 Plate SECC 1 6 Handle PA 1 7 Out casing SPCC 1 8 Fan Ø 200 1 9 Motor YJ61 25 1 10 Motor plate SECC 1 11 Plug 240 415V 16A 1 12 Power cord H07RN F 4G 2 5 mm2 1 13 Relay holder SECC 1 14 Relay 25A 1 No Spare part Specifications QTY 15 Knob PA 1 16 Thermostat YT WN16 1 17 Mica plate Mica 1 18 Switch 16A 1 19 Control box of spot welding SPCC 1 20 Control box SPCC 1 21 Lamp cover PC 1 22 Fee...

Page 15: ... pressing plate PP 1 10 Net SPCC 1 11 The maple leaves clamp PA 1 12 Relay bracket SECC 1 13 Air duct stent SECC 1 14 The motor bracket SECC 1 15 cylindrical SECC 1 No Spare part Specifications QTY 16 The base SECC 1 17 The blades Ø 300mm 0 7mm AL 1 18 The motor AC 380 400V 50 Hz 1 19 The power cord H07RN F 4G 2 5 mm2 1 6m 1 20 The plug 240 415V 16A 1 21 Rotary switch XK233 4 250V 15A 1 22 capacit...

Page 16: ... conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A We Trotec GmbH declare in sole responsibility that the product designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006 42 EC Product model Product TDS 30 M TDS 50 M Product type ceramic heater Year of manufacture as of ...

Page 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: