![Trotec TDS 10 M Original Instructions Manual Download Page 15](http://html.mh-extra.com/html/trotec/tds-10-m/tds-10-m_original-instructions-manual_1171931015.webp)
EN
15
ceramic heater TDS 30 M / TDS 50 M
Overview of spare parts and spare parts list TDS 50 M
Note!
The position numbers of the spare parts differ from those
describing the positions of the components mentioned in these
instructions.
No.
Spare part
Specifications
QTY
1
Switch knob
PA
1
2
Temperature control
knob
PA
1
3
Chimney
PC/186C
1
4
Air duct
PA66+30%GF
1
5
Out of the wind
PA66+30%GF V0
1
6
The handle
PA
1
7
MATS
PP
1
8
Line pressing board
PP
1
9
Line pressing plate
PP
1
10
Net
SPCC
1
11
The maple leaves clamp PA
1
12
Relay bracket
SECC
1
13
Air duct stent
SECC
1
14
The motor bracket
SECC
1
15
cylindrical
SECC
1
No.
Spare part
Specifications
QTY
16
The base
SECC
1
17
The blades
Ø 300mm 0.7mm AL
1
18
The motor
AC 380-400V 50 Hz
1
19
The power cord
H07RN-F 4G 2.5 mm
2
*
1.6m
1
20
The plug
240/415V 16A
1
21
Rotary switch
XK233-4/250V 15A
1
22
capacitance
CBB61/0.8μF 50/60Hz
500V
1
23
Delay time limit of the
warm
KSD301/250V/10A/K45 1
24
The thermostat
250V/16A/85 °C/T250
1
25
Limit the warm
KSD301-V/250V/16A/
70 °C
1
26
PTC
220-240V 50Hz 4500W 1
27
Relay
AC400V 25A T70 10E4
1
28
Fuse
AC250V 10A TF=121 °C 1