![Trotec TDS 10 M Original Instructions Manual Download Page 11](http://html.mh-extra.com/html/trotec/tds-10-m/tds-10-m_original-instructions-manual_1171931011.webp)
EN
11
ceramic heater TDS 30 M / TDS 50 M
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Technical annex
Technical data
Parameter
Value
Model
TDS 30 M
TDS 50 M
Heating capacity
level 1:
level 2:
level 3:
50 W
3300 W
5000 W
80 W
6000 W
9000 W
Air flow rate
575 m³/h
1180 m³/h
Operating range
-15 °C to +30 °C -15 °C to +30 °C
Mains connection
380–400 V / 50 Hz 380–400 V / 50 Hz
Max. power input
5000 W
9000 W
Nominal current
consumption
7.6 A
13.7 A
Fusing
10 A
16 A
Plug type
CEE 16 A, 5-pin
CEE 16 A, 5-pin
Cable length
1.15 m
1.15 m
Sound pressure level
(at a distance of 1 m)
53 dB(A)
53 dB(A)
Overheating
protection
98 °C
121 °C
Dimensions (depth x
width x height)
250 x 205 x
360 mm
347 x 267 x
455 mm
Minimum distance to
walls and other
objects
top (A):
rear (B):
sides (C):
front (D):
250 cm
150 cm
50 cm
200 cm
250 cm
150 cm
50 cm
200 cm
Weight
4 kg
7 kg