background image

4

EN

pressure switch TDP DS

Improper use

The device is not suitable for the operation of irrigation systems
in business, industry or in public areas (e.g. park areas).
Using the device in swimming pools and the like is prohibited.
The device is not suitable for increasing the pressure of existing
water supply networks.
The device must not be used for aggressive, abrasive, caustic,
corrosive, combustible or explosive pumping media, e.g.:

brine

sandy water

food

cleaning agents

fuels (e.g. petrol, diesel)

oils

greases

petroleum

nitro-cellulose thinner

waste water from lavatories and urinal installations

The device must not be used at freezing temperatures.
Any unauthorised changes, modifications or alterations to the
device are forbidden.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the operating manual, especially
the Safety chapter.

Setting the switch-on pressure may only be carried out by
specialist companies for water installation.

Electrically skilled person

Electrically skilled personnel must be able to read and
understand electric circuit diagrams, to put electrical systems
into service and to maintain them, to wire control cabinets, to
ensure the functionality of electrical components and to identify
possible hazards from electrical and electronic systems.

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains

feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.

2. Do not reconnect a defective device to the mains.

Summary of Contents for TDP-DS

Page 1: ...TRT BA TDPDS TC2019 61 002 EN TDP DS EN OPERATING MANUAL PRESSURE SWITCH...

Page 2: ...44133 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all...

Page 3: ...e cable for damage The use of extension cables which are not approved for outdoor use can result in injuries due to electric shock Before performing any work on the device in case of leaks in the wate...

Page 4: ...st be able to read and understand electric circuit diagrams to put electrical systems into service and to maintain them to wire control cabinets to ensure the functionality of electrical components an...

Page 5: ...ff the connected pump The restart button on the pressure switch is used for restarting the connected pump manually e g when the device switches the pump off because the pump is running dry In addition...

Page 6: ...age it during unwinding Start up Positioning The device is installed between a pump and one more extraction points e g a water tap or a garden sprayer The following conditions shall be applied The pre...

Page 7: ...mp from the mains voltage Switch the device off and remove the mains plug from the mains socket 2 Open a consumer at the end of the pressure side e g water tap or garden sprayer so that the remaining...

Page 8: ...inated Info It is helpful to fill the suction hose with water to support the suction procedure of the pump To do so the end of the suction hose has to be provided with a backflow preventer Please obse...

Page 9: ...es on or off The LEDs Power On 9 Pump On 8 and Alarm 7 are illuminated green yellow red Turn pressure setting screw 2 5 times towards the minus sign The pressure is reduced by approx 0 5 bar Shutdown...

Page 10: ...remove any existing leakages Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical co...

Page 11: ...sposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You wi...

Page 12: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: