pressure switch TDP DS

Setting the switch-on pressure

Warning

Setting the switch-on pressure may only be carried out
by specialist companies for water installation.

The device is equipped with a pressure setting screw (4). The
setting screw is used to set the pressure value at which the
device switches on the connected pump. For more detailed
information about the required pump pressure please refer to
the start-up chapter.
Please proceed as follows to set the switch-on pressure:

1. Turn the pressure setting screw (4) towards the minus sign

to reduce the switch-on pressure. The minimum switch-on
pressure (screw all the way to the minus sign) is 1.5 bar.

ð

Every 360° turn decreases the pressure for approx.
0.2 bar.

2. Turn the pressure setting screw (4) towards the plus sign

to increase the switch-on pressure. The maximum switch-
on pressure (screw all the way to the plus sign) is 2.5 bar.

ð

Every 360° turn increases the pressure for approx.
0.2 bar.

4

Note for setting the switch-on pressure:

The switch-on pressure is set too low:

– When the tap is opened, the pump does not start

operating.

– The LED 

Power On

 (9) is illuminated in green.

– Turn pressure setting screw towards the plus sign.

The switch-on pressure is set too high:

– The dry-run protection is activated and the pump does

not start operating.

– The LEDs 

Power On

 (9) and 

Pump On

 (8) are illuminated

(green / yellow).

– Turn pressure setting screw towards the minus sign.

Switch-on pressure is set close to the maximum pressure
of the pump:

– The pump operates continuously or frequently switches

on or off.

– The LEDs 

Power On

 (9), 

Pump On

 (8) and 

Alarm

 (7) are

illuminated (green / yellow / red).

– Turn pressure setting screw 2.5 times towards the

minus sign.

– The pressure is reduced by approx. 0.5 bar.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

If you like to disconnect the pressure switch from the water
network, (e.g. for cleaning, maintenance or storing during
winter), proceed as follows:

1. Disconnect the pressure switch from the power supply by

plugging the mains plug out of the mains socket.

2. Afterwards, disconnect the power supply of the pump from

the pressure switch.

3. Open a tap that is connected to the pressure switch to

release any remaining water pressure.

4. Disconnect the connection on the water outlet of the

pressure switch. Afterwards, disconnect the connection on
the water inlet of the pressure switch.

5. Empty the pressure switch (and your pump as well).

Carefully dry pressure switch and power cable.

Note

During winter, store pressure switch (and your pump)
in a dry room and protected against frost.

Errors and faults

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The connected pump does not start operating:

Check the power connection.

Check the power cable and mains plug for damage.

Check the on-site fusing.

Check the necessary initial pressure of the pump.

Check whether enough water is available and make sure
the water can be sucked by the pump without any
problems.

Summary of Contents for TDP-DS

Page 1: ...TRT BA TDPDS TC2019 61 002 EN TDP DS EN OPERATING MANUAL PRESSURE SWITCH...

Page 2: ...44133 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all...

Page 3: ...e cable for damage The use of extension cables which are not approved for outdoor use can result in injuries due to electric shock Before performing any work on the device in case of leaks in the wate...

Page 4: ...st be able to read and understand electric circuit diagrams to put electrical systems into service and to maintain them to wire control cabinets to ensure the functionality of electrical components an...

Page 5: ...ff the connected pump The restart button on the pressure switch is used for restarting the connected pump manually e g when the device switches the pump off because the pump is running dry In addition...

Page 6: ...age it during unwinding Start up Positioning The device is installed between a pump and one more extraction points e g a water tap or a garden sprayer The following conditions shall be applied The pre...

Page 7: ...mp from the mains voltage Switch the device off and remove the mains plug from the mains socket 2 Open a consumer at the end of the pressure side e g water tap or garden sprayer so that the remaining...

Page 8: ...inated Info It is helpful to fill the suction hose with water to support the suction procedure of the pump To do so the end of the suction hose has to be provided with a backflow preventer Please obse...

Page 9: ...es on or off The LEDs Power On 9 Pump On 8 and Alarm 7 are illuminated green yellow red Turn pressure setting screw 2 5 times towards the minus sign The pressure is reduced by approx 0 5 bar Shutdown...

Page 10: ...remove any existing leakages Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical co...

Page 11: ...sposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You wi...

Page 12: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: