Page 1: ...TRT BA PV4 MID PS TC2019 63 001 EN PV4 MID PS EN OPERATING MANUAL MULTIPLE SOCKET OUTLET...

Page 2: ...mediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious...

Page 3: ...bed in this manual is prohibited Non observance renders all claims for liability and guarantee null and void Intended use The device serves as mobile multiple socket outlet The multiple socket outlet...

Page 4: ...e description The device serves for the mobile power supply on varying application devices It comes with the following device characteristics 4 safety sockets CEE 7 3 with one PlugSafe appliance each...

Page 5: ...t for seal 10 Safety socket cover 11 PlugSafe appliance 12 Seal 13 Anchoring for seal 14 Open end of seal 15 Terminals for neutral conductors 16 Multifunction button 17 Metrological LED 18 Backlit LC...

Page 6: ...20 mA Accuracy Active energy class B according to EN 50470 3 MID Active energy class 1 according to EN 62053 21 NO MID Reactive energy class 2 according to EN 62053 23 S0 output Passive optoisolated...

Page 7: ...orage temperature is the same as the range given in the Technical data chapter Start up Warning of electrical voltage Work on the electrical components must only be carried out by a qualified electric...

Page 8: ...unauthorised access by means of one or more seals 12 Securing the multiple socket outlet can be realised whether a plug has been inserted into the safety socket 5 or not One seal 12 per plug or safet...

Page 9: ...nctions or settings are controlled via the multifunction button 16 The symbol indicates a standard value the indicates a bidirectional value All total counter values kWh kVAh kvarh can be assigned to...

Page 10: ...nter records the total consumption If required the partial counter can be activated in addition to record a value during a certain period of time The partial counter can be started stopped and reset 1...

Page 11: ...unction button 16 for 3 s During these 3 seconds 3 bars will be displayed next to the Stop sequence Once the Stop sequence is completely indicated the partial counter will be stopped The symbol will b...

Page 12: ...enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe t...

Page 13: ...is reached the inspection intervals may be extended to max once per year Checking the residual current device Info Generally the power supply of all consumers is interrupted for testing the residual...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...