background image

13

EN

Operating manual – PCPS 10-16V / PCPS 11-16V

5. Let go of the on/off switch (13) to stop the device when the

desired filling volume has been reached.

ð

The LED work lamp (14) goes out.

13

6. Remove the nozzle (17) from the device.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable of
the charger out of the mains socket.

If required, allow the device to cool down.

Remove the battery from the device (see Start-up chapter).

Clean the device according to the Maintenance chapter.

Store the device according to the Storage chapter.

Available accessories

Warning

Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.

Accessories

Article number

Spare battery 16V 2 Ah

6.200.000.205

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Troubleshooting tasks which require the housing to be opened
must only be carried out by an authorized specialist electrical
company or by Trotec.

Slight smoke or odour are emitted during first use:

This is not a fault. These phenomena disappear after a
brief runtime.

The battery does not charge:

Check whether the battery is correctly connected to the
quick charger.
Slide the battery into the quick charger in a way that the
battery terminals engage in the quick charger. The battery
must lock in place in the quick charger.

Check the power connection.

Check the power cable and mains plug for damages.

Check the fuse (home).

Check the quick charger for damages. Should the quick
charger be damaged, stop using it. Contact the Trotec
customer service.

Check the battery terminals for dirt. Remove any dirt.

The battery might be defective and have to be replaced.
Only use batteries of the same type.

The device does not start:

The battery power might be too low. Recharge the battery.

Check whether the battery is correctly connected to the
device.
Slide the battery onto the device in a way that the battery
terminals engage. The battery must lock in place in the
device.

Check the battery terminals for dirt. Remove any dirt.

Info

Wait for at least 10 minutes before switching the
device back on.

Summary of Contents for PCPS 10-16V

Page 1: ...TRT BA PCPS10 16V PCPS11 16V TC 001 EN PCPS 10 16V PCPS 11 16V EN OPERATING MANUAL...

Page 2: ...ith this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed Wear ear protection Info...

Page 3: ...pment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Prevent unintentional starting Ensure the switch is in the of...

Page 4: ...tery packs may create a risk of injury and fire When battery pack is not in use keep it away from other metal objects like paper clips coins keys nails screws or other small metal objects that can mak...

Page 5: ...ialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket and the battery from the device Hold onto the mains plug while pulling the power...

Page 6: ...omatically The cordless air pump PCPS 11 16V is suited for inflating and deflating inflatable products with a large volume such as air mattresses or rubber dinghies Device depiction Cordless compresso...

Page 7: ...ments for air pump 2 x Universal adapter short 1 x Universal adapter long 1 x Transport case 1 x Manual Technical data Parameter Value Model PCPS 10 16V PCPS 11 16V Nominal voltage 16 V 16 V Max press...

Page 8: ...mains socket Allow the device to cool down Remove the battery from the device The supplied Li ion batteries are subjects to the requirements of dangerous goods legislation Observe the following when t...

Page 9: ...es below 10 C or above 40 C The battery is partially charged upon delivery to avoid damage to the battery caused by a deep discharge Prior to initial start up and when the battery is low only the red...

Page 10: ...ld of application the following valve adapters can be connected either directly to the device or via the optional compressed air hose 18 No Designation Description 19 Presta valve adapter To be used w...

Page 11: ...connected to the air inlet or air outlet No Description 31 To be used with inflatables fitted with a vent valve 32 To be used with inflatables fitted with a screw on valve venting with the valve deta...

Page 12: ...this value amounts to 0 2 Press and hold the plus 37 or minus 35 button for approx 2 s The segment display 38 flashes 3 Use the plus 37 and minus 35 buttons to set the desired pressure value 4 Wait un...

Page 13: ...Tips and notes on handling the cordless air pump General information Keep the venting slots clear to prevent the motor from overheating The device is not suitable for continuous operation The device...

Page 14: ...following list Troubleshooting tasks which require the housing to be opened must only be carried out by an authorized specialist electrical company or by Trotec Slight smoke or odour are emitted durin...

Page 15: ...s plug or the battery with wet or damp hands Switch off the device Allow the device to cool down completely Remove the battery from the device Warning of electrical voltage Maintenance tasks which req...

Page 16: ...site www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent nega...

Page 17: ......

Page 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: