background image

Trotec GmbH

Grebbener Str. 7
D-52525 Heinsberg

   

 

+49 2452 962-400
+49 2452 962-200

[email protected]
www.trotec.com

Summary of Contents for PAE 29

Page 1: ...TRT BA PAE29 TC2020 03 002 EN PAE 29 EN OPERATING MANUAL AIR COOLER...

Page 2: ...y via the following link PAE 29 https hub trotec com id 44208 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or i...

Page 3: ...he water Health hazard Note that high humidity levels may enhance the growth of biological organisms in the environment Make sure that objects in the surroundings of the device do not become wet or da...

Page 4: ...e is not a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Note Do not operate the device wi...

Page 5: ...tilation flaps and ventilation flaps with swing function 3 Water tank with filling level indicator 4 Wheels 5 Transport handle and compartment for the remote control 6 Air inlet with air filter and ev...

Page 6: ...tion filter to dry prior to storage Otherwise the device may distribute a musty smell after restart Hold onto the mains plug while pulling the power cable out of the mains socket When the device is no...

Page 7: ...on the water outlet before filling the device Note Fill the device with fresh drinking water only The water temperature must not exceed 40 C Info If possible change the water every 3 days to prevent b...

Page 8: ...ert the evaporation filter 9 and the air filter 10 7 Make sure that the device is neither damp nor wet on the outside Otherwise wipe it dry Inserting evaporation filter and air filter Note When set to...

Page 9: ...On Off button Switching the device on or off 14 Speed button For setting the fan speed 15 Swing button Switching the swing function on or off 16 Timer button Switching the timer on or off 1 h 9 h 17...

Page 10: ...nately to generate a pleasant natural air stream Please proceed as follows to activate air freshening 1 Press the Mode button 17 until the Air freshening LED 24 is illuminated The fan speed starts at...

Page 11: ...nking water only Optionally you can add ice cubes made of drinking water for additional cooling Observe the minimum and maximum filling level at the filling level indicator The water tank must be fill...

Page 12: ...operation Check whether air cooling mode is activated Check the filling level of the water tank see chapter Filling the water tank Check whether there are any objects blocking the pump inlet Make sur...

Page 13: ...crews X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Clean the water tank Check air inlets and outlets for dirt...

Page 14: ...onents from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Cleaning the water tank The water tank should be...

Page 15: ...g water Cleaning the air filter The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults Warning Ensure that the air fil...

Page 16: ...ork Note Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to...

Page 17: ...nsiderable time Store the device according to the Storage chapter Technical annex Technical data Parameter Value Model PAE 29 Max evaporation performance 330 ml h Air flow rate 100 m h Mains connectio...

Page 18: ...e trotec com shop The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: