Operating manual – infrared radiant heater IRD 1200 / IRD 1800 / IRD 2400 / IRD 3200
Installation
When installing the device, observe the minimum distances
from walls and other objects as described in the Technical data
chapter.
•
Minimum distance of 220 cm and maximum distance of
270 cm from the floor.
•
Minimum distance of 100 cm to the front or from objects.
•
Minimum distance of 30 cm from the ceiling in case of
wall mounting or, for technical reasons, 19.5 cm in case of
ceiling mounting.
•
Minimum distance of 20 cm to the sides.
•
For installation in bathrooms or washing rooms, observe
the national regulations on safety distances.
•
Do not install the device directly in front of a wall socket.
The socket should be located next to the device. If the
device is installed on a pitched ceiling, the socket should
be located at the bottom side of the device.
•
Do not install the device directly behind a door.
•
Never install the device in a way that it radiates directly
onto walls or other objects.
•
Only install the device in a horizontal position.
•
Please note that the minimum distance to the front also
applies to objects mounted on the ceiling, e.g. fans, lamps
or sprinkler systems.
220 cm
30 cm
20 cm
20 cm
100 cm
Info
Please note that in case of ceiling mounting the
distance from the ceiling is 19.5 cm due to the length
of the mounting brackets.
For wall mounting, the minimum distance of 30 cm
from the ceiling applies.
The following is required for installation:
•
a pencil for marking the drill holes
•
a suitable drill
•
wall plugs appropriate for the structure of the wall and for
the device weight
•
a screwdriver
•
a spirit level
Notice
Always install the device with the help of other
persons.
1. Measure the distance between the holders on the device
and use this value for the distance between the drill holes.
2. Mark the drill holes on the wall / ceiling. Please note the
mounting brackets must be fastened
vertically
.