11
EN
Operating manual – infrared radiant heater IRD 1200 / IRD 1800 / IRD 2400 / IRD 3200
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Info
If you switch off the device via the remote control, the
device will be set to standby mode. If standby
operation is not required, you can switch the device off
via the on/off switch (2).
•
Switch off the device by pressing the Power button (23) on
the remote control. The operating light flashes. Then set
the on/off switch (2) on the device to
0
.
Switch the device off by setting the on/off switch (1) to the
OFF
position.
•
Allow the device to cool down completely.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.
Errors and faults
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Noise generation (clicking) during switch-on or cooling:
•
This is not a fault. The device's metal parts expand when
heated and contract when cooling, and thus generate
noise. It is a perfectly normal process. No measures are
required.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device does not emit heat:
•
The heating rod might be defective. Have a defective
heating rod replaced by a specialist electrical company.
•
Check the heating level on the segment display. If
P0
is
displayed, the device is running in standby mode.
Switch the device on by selecting another heating level
between
P1
and
P3
.
•
Check the on/off switch. If the on/off switch is set to the
0
position, the device is switched off.
Switch the device on.
•
Check the operating light. If the operating light flashes red,
the device is running in standby mode.
Switch on the device by selecting a heating level via the
remote control.
•
Contact a specialist electrical company.
The heat output is low:
•
Strong wind or cold temperatures in outdoor areas can
impair the device's heat output.
•
Check whether the device is installed in the correct
position. The device may be installed too high or the
inclination angle may be incorrect.
•
The device is undersized for the area to be heated.
•
The heating rod might be defective. Have a defective
heating rod replaced by a specialist electrical company.
RCD or another fuse trips:
•
Check the fuse. Switch off any other devices to reduce the
load on the line.
The device slightly vibrates during switch-on and then
stops vibrating:
•
Slight vibrations during switch-on are a normal process.
No measures are required.
The device does not respond to the infrared remote control:
•
Check whether the distance between remote control and
device is too large and reduce it if necessary.
•
Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.
•
Check the charging status of the batteries and change
them if required.
•
If the batteries have only just been changed, check them
for correct polarity and change them if required.
Notice
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
Summary of Contents for IRD 1200