![Trotec IDS 30 F Original Instructions Manual Download Page 12](http://html.mh-extra.com/html/trotec/ids-30-f/ids-30-f_original-instructions-manual_1172027012.webp)
12
EN
oil heater IDS 30 F
Establishing the oil supply
Quick couplings are used to connect the device to an external
tank or the optional jerrycan.
ü
Switch the device off according to the Shutdown chapter.
ü
Before attempting to connect the external tank, wait until
the device has cooled down completely.
ü
Only use fuel suitable for the device (see technical data).
1. Position the device on firm, level and incombustible
ground.
2. Unscrew the cover from the tank connection of the
external tank.
3. Unscrew the cover of the device from the tank connection
of the device.
4. Attach the feed and return hose to the tank connection of
the external tank using the quick couplings.
5. Attach the feed and return hose to the tank connection of
the device using the quick couplings.
6. Make sure that the hose is firmly attached to avoid
leakage.
7. The device is now connected to the oil supply.
ON
ON
Positioning
A number of spatial and technical conditions have to be
considered for the selection of the device's installation site.
Non-observance may impair the proper functioning of the device
or the accessories or can entail risks of personal injury and
property damage.
The following is to be observed for positioning:
•
The device may only be operated on roofed over surfaces.
•
The device is to be set up in a stable position on
incombustible ground.
•
The device must be set up in close proximity to a flue, an
outer wall or on an open, ventilated surface.
•
The device must be connected to a properly secured mains
power socket.
•
The room where the device is positioned must be
sufficiently ventilated.
Ensure a sufficient fresh air supply, especially when there
are people or animals in the same room with the device!
•
The minimum distance between the wall and the air inlet
opening of the device must be at least 2 m (see figure).
•
The minimum distance between the device and
combustible materials must be at least 3 m.
•
The inlet and outlet openings must not be covered.
•
There must be no walls or large objects near the device.
•
There must be a sufficient number of fire extinguishers
available.