The flame goes out during combustion:

Make sure the air supply is unobstructed. If required, clean
the air intake opening.

Check the filling level of the tank. Refill with fuel if the tank
is empty (see chapter Operation).

Check the fuel filter in the fuel pump for dirt. If it is dirty,
please contact the customer service.

Check the fuel for contaminations and replace it if
required.

Power failure: In the event of a power failure the ignition is
extinguished, the device switches off immediately. After a
power failure the device will not restart automatically, it
has to be started via the on/off switch.

There is a fuel leak:

Check whether too much fuel was filled in. Drain the fuel if
necessary, see chapter Draining the tank.

Check the drain screw for tight fit and retighten it if
necessary.

Check the sealing at the drain screw and replace it if
damaged.

Check the fuel pump for leaks. If there are doubts about
the proper condition of the fuel pump, please contact the
customer service.

The device emits smoke or dust:

Check the mains voltage.

Check the fuel for contaminations and replace it if
required.

Check the tank for contaminations and drain it if required
(see chapter Maintenance). Refill with clean fuel.

The flame emerges from the air outlet:

Check the mains voltage.

Check the fuel for contaminations and replace it if
required.

Check the tank for contaminations and drain it if required
(see chapter Maintenance). Refill with clean fuel.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.

Filling the tank

The fuel tank cap is located at the side of the 

IDS 20 D / IDS 30

D

. The images in the description below show the IDS 30 D by

way of example.

ü

Before attempting to fill the tank, wait until the device has
cooled down completely.

ü

Only use fuel suitable for the device (see technical data).

1. Position the device on firm, level and incombustible

ground.

2. Unscrew the fuel tank cap (7).

7

Summary of Contents for IDS 20D

Page 1: ...TRT BA IDS20D IDS30D TC2018 31 001 EN IDS 20 D IDS 30 D EN ORIGINAL INSTRUCTIONS OIL HEATER ...

Page 2: ...is symbol indicates dangers to the life and health of persons due to hot surface Warning This signal word indicates a hazard with an average risk level which if not avoided can result in serious injury or death Caution This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Note This signal word indicates important information e g mater...

Page 3: ...r Never insert any objects or limbs into the device Do not cover or transport the device during operation Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Do not sit on the device This appliance is not a toy Keep away from children and animals Do not leave the device unattended during operation Check accessories and co...

Page 4: ...e Work on the electrical components must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket Hold onto the mains plug while pulling the power cable out of the mains socket Warning of flammable substances Handling fuels entails a risk of fire Take sufficient precautions when handling fuels su...

Page 5: ...eplaced Information about the device Device description The directly fired oil heater IDS 20 D serves the purpose of heating the room air so as to quickly heat large well ventilated rooms The oil heater runs on EL fuel oil kerosene or diesel it must not be used with petrol heavy fuel oil etc It is an oil heater with direct combustion to be installed in roofed outdoor areas or in rooms with a suffi...

Page 6: ...1 2 3 4 5 6 7 8 9 10 11 IDS 30 D 10 9 1 3 4 7 8 5 6 11 No Designation 1 Combustion chamber housing 2 Handle 3 Transport handle 4 Air inlet with protective grid 5 Fan and motor 6 Control panel 7 Tank 8 Fuel tank cap 9 Wheel 10 Air outlet for hot air 11 Fuel pump ...

Page 7: ...ins socket Allow the device to cool down sufficiently When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Assembly and installation Scope of delivery 1 x Oil heater 1 x Transport handle 2 x Wheel 1 x Insta...

Page 8: ...rt frame IDS 20 D 1 Connect the transport frame to the rear of the device 2 Make sure that the holes for the screws are positioned flush above each other 3 Bolt the screws to the device and frame IDS 30 D 1 Connect the transport frame to the rear of the device 2 Make sure that the holes for the screws are positioned flush above each other 3 Bolt the screws to the device and frame ...

Page 9: ... of the device must be at least 2 m see figure There must be no walls or large objects near the device The inlet and outlet openings must not be covered There must be a sufficient number of fire extinguishers available 25 30 35 40 45 5 10 15 20 2 m 2 m 2 m 2 m 3 m Start up Check the scope of delivery of your device for completeness If an accessory part is missing please contact the Trotec customer...

Page 10: ...n optional thermostat is connected to the optional thermostat socket ü The device is equipped with an optional thermostat socket ü An optional thermostat is connected to the device 1 Prepare the device for operation by setting the connected thermostat 2 Please note the instructions provided with the thermostat 3 Set the on off switch 13 to position I IDS 30 D The IDS 30 D comes with a heating leve...

Page 11: ...make any modifications or repairs on the device Unauthorised modifications can lead to serious injuries or death Have a certified specialist workshop perform the repair work The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power connection Check t...

Page 12: ...k the tank for contaminations and drain it if required see chapter Maintenance Refill with clean fuel Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical company or to Trotec for r...

Page 13: ...k out uncontrollably 6 Dispose of the fuel according to national regulations Technical annex Technical data Parameter Value Model IDS 20 D IDS 30 D Combustion direct direct Air flow rate 350 m h 605 m h Fan axial fan axial fan Nominal heat output 20 kW 38 4 kW Ventilation air changes per hour at least 2 ACH at least 2 ACH Temperature increase ΔT 100 C 75 C Max fuel consumption 2 04 l h 3 66 l h Ta...

Page 14: ... according to the national regulations Declaration of conformity The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 42204 Declaration of conformity In accordance with the EC Machinery Directive 2006 42 EC Annex II part 1 Section A Herewith we Trotec GmbH Co KG declare that the machinery designated below...

Page 15: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...