EN
Operating manual – Oil heater IDE 20 / IDE 30 / IDE 50 / IDE 60 / IDE 80
7
The devices may only be operated by accordingly instructed
persons.
Observe the personnel qualification.
Switching on the oil heater
Switching off the oil heater
• Switch off the device by setting the selector switch to position
0.
• If you use a thermostat, switch off the device using the
settings of the controller (e. g. by setting a lower temperature
at the thermostat).
The flame goes out and the fan continues to run for approx. 90
seconds in order to cool down the burner.
Damage to the device due to overheating! Never
switch off the device by pulling the mains plug. This
may lead to overheating!
Switch off the device properly.
Only pull the mains plug once the fan motor has
stopped completely.
Restart after troubleshooting
During initial start-up and after the fuel oil circuit has been
drained completely, the fuel oil supply to the nozzle may be
insufficient. In this case, the flame monitoring system will
respond and the device will be blocked.
• Wait for approx. 1 minute.
• Switch the device on.
• If the device still does not start:
• Make sure that there is fuel left in the tank.
• See chapters General safety and Troubleshooting.
Safety devices
The oil heater is equipped with an electronic flame and maximum
temperature monitoring system working with a photo cell and a
safety thermostat.
Functions and operation
0
10s
5s
5s
0-60s
0-60s
10s
5s
5s
0-60s
10s
5s
5s
21°C
20°C
19°C
Room temperature:
Wait until the
fan has come
to a standstill!