Operating manual – Oil heater IDE 20 / IDE 30 / IDE 50 / IDE 60 / IDE 80

9

Risk of death due to improper repair! Never try to
make any modifications or repairs on the device. 
Unauthorised modifications can lead to serious
injuries or death. 
Have a certified specialist workshop perform the
repair work.

Troubleshooting

Faults and troubleshooting

Problem

Cause

Troubleshooting

Fan does not start and 
flame does not ignite

Controller set 
incorrectly

Check if the controller is set 
correctly (e. g. the 
temperature set at the 
thermostat must be higher 
than the room temperature).

Controller faulty

Have the controller 
exchanged by the customer 
service.

Fan does not start or 
switches off during 
start-up or operation

No power supply

Check the characteristics of 
the electrical system  
(230 V - 1~ - 50 Hz).
Check the functionality and 
position of the selector 
switch.
Check the fuse for 
soundness.

Fan switches off during 
start-up or operation

Flame present prior 
to ignition of the 
transformer

Contract the customer 
service to have the device 
cleaned and fuel oil residues 
removed from the 
combustion chamber.

Photo cell faulty

Have the photo cell 
exchanged by the customer 
service.

Motor winding 
interrupted or blown

Have the motor exchanged 
by the customer service.

Motor bearing 
blocked

Have the motor bearing 
exchanged by the customer 
service.

Motor capacitor 
blown

Have the motor capacitor 
exchanged by the customer 
service.

Fan switches off during 
start-up or operation

No ignition

Check the connections of the 
ignition cables at the 
electrodes and the 
transformer.
Check the position and the 
distance of the electrodes.

Check whether the 
electrodes are clean.

Have the transformer 
exchanged by the customer 
service.

Flame monitoring
system faulty

Have the flame monitoring 
system exchanged by the 
customer service.

Photo cell faulty

Have the photo cell cleaned 
or exchanged by the 
customer service.

Fan switches off during 
start-up or operation

Burner is supplied 
with no or 
insufficient fuel oil

Contract the customer 
service to have the coupling 
between the pump and the 
motor checked for 
soundness.
Contract the customer 
service to have the fuel oil 
circuit checked for intruded air 
and to have the lines and filter 
seal checked for tightness.
Contract the customer 
service to have the nozzle 
cleaned or exchanged.

Magnet valve faulty

Contract the customer 
service to have the electrical 
connections checked.
Contract the customer 
service to have the safety 
thermostat LI checked.
Contract the customer 
service to have the magnet 
valve cleaned or exchanged.

Internal error of the 
electronic control 
unit

Contract the customer 
service to have the control 
unit reset; try at least twice. If 
the problem persists, have 
the control unit changed.

Fan starts and flame 
burns with smoke 
formation

Insufficient 
combustion air 
supply

Remove all obstacles and 
obstructions from the inlet 
and/or outlet openings.
Have the supporting disc of 
the burner cleaned by the 
customer service.

Used fuel oil 
contaminated or 
contains water

Replace used fuel oil with 
clean fuel oil.
Clean the fuel oil filter.

Air inside the fuel oil 
circuit

Have the lines and the fuel oil 
filter checked for tightness by 
the customer service.

Insufficient fuel oil 
quantity at the 
burner

Contract the customer 
service to:
have the pump pressure 
checked.
have the nozzle cleaned or 
exchanged.

Excessive fuel oil at 
the burner

Contract the customer 
service to:
have the pump pressure 
checked.
have the nozzle exchanged.

Device does not switch 
off

Sealing of the 
magnet valve faulty

Have the magnet valve 
exchanged by the customer 
service.

Problem

Cause

Troubleshooting

Summary of Contents for IDE 20

Page 1: ...IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 EN TRT BA IDE20 30 50 60 80 TC 001 EN OPERATING MANUAL OIL HEATER ...

Page 2: ......

Page 3: ...ce if you hand it over to other persons for use The scope of delivery of the oil heater contains Table of contents Information on the use of this manual 1 Scope of delivery 1 General safety 2 Function and product features 2 Technical data 3 Intended and improper use 4 Installation conditions 4 Description of the device 4 Installation and start up 6 Exhaust system 6 Functions and operation 7 Transp...

Page 4: ... health risk Risk of death due to electric shock Only connect the device to technically intact power sources Do not use damaged sockets Hold the plug while pulling the connection cable out of the socket Do not touch electric connection cables with wet hands Protect electric connection cables from damages e g caused by animals Do not modify or repair the device Do not expose the device to any fluid...

Page 5: ...W 50 kW 60 kW 80 kW Air volume flow 600 m h 760 m h 2000 m h 2000 m h 2000 m h Fan axial axial axial axial axial Temperature increase ΔT 85 C 80 C 95 C 75 C 90 C Fuel consumption 1 6 l h 3 4 l h 4 6 l h 5 2 l h 7 8 l h Tank contents 24 l 50 l 68 l 68 l 68 l Chimney connection ø 120 mm ø 120 mm ø 150 mm ø 150 mm ø 150 mm Thermostat connection series series series series series Combustion indirect i...

Page 6: ... stable position on incombustible ground The device is to be installed near a chimney or an outer wall The device must be connected to a properly secured mains power socket The room where the device is positioned must be sufficiently ventilated The minimum distance between the wall and the air inlet opening of the device must be at least 2 m see figure The minimum distance between the device and c...

Page 7: ...he chimney connection Assembly of the chimney adapter For outdoor use and for use in partly closed well ventilated rooms without an exhaust system it is necessary to mount a simple chimney adapter B to the chimney connection C Observe the following The adapter B must have a minimum length of 1 m Bends and elbows in this line are prohibited If the device is used outdoors a weather protection A must...

Page 8: ...hat the fan is moving freely Connect the mains cable to a properly secured mains socket 230 V 50 Hz 10 A On construction sites there must be an RCD upstream of the socket according to VDE 0100 0105 The oil heater is now ready for operation Use the device in accordance with the functions described in the chapter Functions and operation Prior to planning of the exhaust system inform the competent ch...

Page 9: ... overheating Switch off the device properly Only pull the mains plug once the fan motor has stopped completely Restart after troubleshooting During initial start up and after the fuel oil circuit has been drained completely the fuel oil supply to the nozzle may be insufficient In this case the flame monitoring system will respond and the device will be blocked Wait for approx 1 minute Switch the d...

Page 10: ...he customer service Assemble the components in reverse order Cleaning the oil heater Wipe the outside of the device with a damp cloth Painted and plastic surfaces must not be scrubbed Do not use any cleaners containing solvents The fuel must be drained from the tank of the oil heater and collected Oil heater In the European Union electronic equipment must not be treated as domestic waste but must ...

Page 11: ...e monitoring system faulty Have the flame monitoring system exchanged by the customer service Photo cell faulty Have the photo cell cleaned or exchanged by the customer service Fan switches off during start up or operation Burner is supplied with no or insufficient fuel oil Contract the customer service to have the coupling between the pump and the motor checked for soundness Contract the customer...

Page 12: ...ized changes of the factory supplied device version this declaration loses its legal validity Device version Diesel oil kerosene heater fan Series IDE 20 IDE 30 IDE 50 IDE 60 IDE 80 Applicable regulations 2006 42 EC 2006 95 EC 2004 108 EC 2011 65 EC Machinery Directive Low Voltage Directive EMC Directive RoHS Applied standards EN 13842 2004 EN 60335 1 2012 EN 60335 2 102 2006 A1 EN 62233 2008 EN 5...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: