oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D
Assembly of transport handle and frame (IDE 30 D / 50 D /
60 D / 100 D)
1. Place the device on the frame. Make sure that the holes for
the screws are positioned flush above each other.
2. First, bolt the 4 small screws to the frame.
3. Screw the nuts to the screws from below.
4. Place the transport handle on the rear section.
5. Bolt the 4 large screws to the transport handle, device and
frame.
IDX 30 D
THERMOST
AT CONTROL
ROOM TEM
P.
CLOSE
OPEN
Positioning
A number of spatial and technical conditions have to be
considered for the selection of the device's installation site.
Non-observance may impair the proper functioning of the device
or the accessories or can entail risks of personal injury and
property damage.
The following is to be observed for positioning:
•
Do not operate the device for more than 3 month at the
same place. Prior to planning the flue gas system, gather
information about the national legislation and contact a
responsible specialist.
•
The device may only be operated on roofed over surfaces.
•
The device is to be set up in a stable position on
incombustible ground.
•
The device must be set up in close proximity to a chimney,
an outer wall or on an open, ventilated surface.
•
The device must be connected to a properly secured mains
power socket.
•
The room where the device is positioned must be
sufficiently ventilated.
Ensure a sufficient fresh air supply, especially when there
are people or animals in the same room with the device!
•
The minimum distance between walls or other objects and
the air outlet opening of the device must be at least 3 m
(see figure).
The minimum distance between walls or other objects and
the air inlet opening of the device must be at least 2 m
(see figure).
There must be no walls or large objects near the device.
•
The inlet and outlet openings must not be covered.
•
There must be a sufficient number of fire extinguishers
available.
25 30
35
40
45
5
10
15
20
2 m
2 m
2 m
2 m
3 m