10
EN
oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D
Operation
The device may only be used by accordingly instructed persons.
Operating elements
IDE 20 D / IDE 30 D
12
13
14
IDE 50 D / IDE 60 D
12
14
13
IDE 100 D
15
16
13
12
No.
Designation
12
Rotary control thermostat
13
On/off switch
14
Operating LED
15
Target value indication
16
Room temperature indication
Switching the device on
Wear hearing protection.
Excessive noise can lead to hearing loss.
The device continues to operate until the desired room
temperature is reached.
1. Set the on/off switch (13) to position
I
.
ð
The on/off switch (13) is illuminated.
2. Set the rotary control (12) to the desired room
temperature. This value should be higher than the current
room temperature.
3. Ensure a successful ignition.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Note
Damage to the device due to overheating!
Never switch off the device by pulling the mains plug.
This may lead to overheating!
Switch off the device properly. Only remove the mains
plug from the device once the fan motor has stopped
completely.
1. Switch off the device by setting the on/off switch (13) to
position
0
.
ð
The on/off switch (13) is no longer illuminated.
2. Wait until the fan motor has come to a complete standstill.
3. Secure the device against inadvertent switch-on by pulling
the mains plug.
4. Allow the device to cool down completely.
Restart after troubleshooting
During initial start-up and after the fuel oil circuit has been
drained completely, the fuel oil supply to the nozzle may be
insufficient. In this case, the flame monitoring system will
respond and the device will be blocked. Proceed as follows:
1. Wait for approx. 1 minute.
2. Switch the device on.
If the device is still not starting, proceed as follows:
1. Make sure that there is fuel left in the tank.
2. Please refer to the chapters General safety warnings and
Errors and faults.