background image

8

EN

electric heater TDS 20 R / TDS 30 R / TDS 50 R

Errors and faults

Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

The motor might be defective. Have a defective motor
replaced by a specialist electrical company.

The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is switched on, the fan is operating, the heating
is not:

Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.

Check whether the overheating protection has tripped, see
chapter Safety.

The heating resistor might have blown. Have a defective
heating resistor replaced by a specialist electrical
company.

The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.

The fan is not running:

Check whether the device is switched on.

Check the power connection.

Check the power cable and mains plug for damages.

The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.

The air current is reduced:

Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.

Cleaning the housing

Warning of electrical voltage

Never immerse the device in water!

Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.

Summary of Contents for DS 20R

Page 1: ...TRT BA TDS20R TDS30R TDS50R TC2014 15 004 EN TDS 20 R TDS 30 R TDS 50 R EN ORIGINAL INSTRUCTIONS ELECTRIC HEATER ...

Page 2: ...lps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the instructions must be observed You can download the current version of the instructions and the EU declaration of conformity via the following link TDS 20 R https hub trotec com id 39781 TDS 30 R https hub trotec com id 39809 TDS 50 R https hub trotec com id 39810 Safety Read ...

Page 3: ...sert the mains plug into a properly secured mains socket Observe the device s power input cable length and intended use when selecting extensions to the power cable Completely unroll extension cables Avoid electrical overload Before carrying out maintenance care or repair work on the device remove the mains plug from the mains socket Hold onto the mains plug while doing so Switch the device off an...

Page 4: ...ice when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Warning The device is not a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Warning Improper installation entails a risk of fire Do not place the device on combustible ground Do ...

Page 5: ...DS20R TDS 20 R 3kW 1 2 3 4 TDS 20 R 5 TDS 30 R kW TDS30R TDS 30 R 5kW 1 2 3 4 TDS 30 R 5 TDS 50 R kW TDS50R TDS 50 R 9kW 1 2 3 4 TDS 50 R 5 No Designation 1 Transport handle 2 Selection switch for ventilation and heating levels 3 Rotary control thermostat 4 Air outlet 5 Air inlet ...

Page 6: ...cope of delivery 1 x Electric heater 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up Info Odours might arise upon initial start up or after a longer period of non use When positioning the device obser...

Page 7: ...tat The room thermostat controls the room temperature automatically TDS 20 R When exceeding the set value both the heating and the ventilation will be switched off TDS 30 R TDS 50 R When the set value is exceeded the heating switches off while the fan keeps running until the heater has cooled down sufficiently As soon as the heater has cooled down sufficiently the heater will be switched back on S...

Page 8: ...eck the power connection Check the power cable and mains plug for damages The fan motor might be defective Have a defective fan motor replaced by a specialist electrical company The air current is reduced Check the air inlet and outlet Make sure that air inlet and outlet are not obstructed Remove any dirt Observe the minimum distance from walls or other objects according to the technical data The ...

Page 9: ...n 1 N PE 230 V 50 Hz 3 N PE 400 V 50 Hz 3 PE 400 V 50 Hz Max power input 3000 W 5000 W 9000 W Nominal current consumption 13 04 A 7 22 A 13 A Fusing 16 A 16 A 16 A Plug type CEE 7 7 CEE 16 A 5 pin CEE 16 A 5 pin Cable length 1 37 m 1 20 m 1 20 m Sound pressure level at a distance of 1 m 53 dB A 56 dB A 56 dB A Weight 3 kg 5 kg 6 5 kg Dimensions length x width x height 210 x 195 x 270 mm 275 x 220 ...

Page 10: ...s of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 39781 Declaration of conformity In accordance with the EC Machinery Directive 2006 42 EC Annex II part 1 Section A Herewith we Trotec GmbH Co KG declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Dire...

Page 11: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: