EN
5
digital multimeter BE49
Often several values are indicated on the device, for instance
CAT III/ 1000 V and CAT IV/600 V. In these cases, different
maximum voltages apply to the stated scopes of application. If
no measurement category is specified, the measurement device
is only considered as safe in measurement category CAT I.
Device depiction
1
3
4
6
7
2
8
12
11
9
14
10
13
5
No.
Designation
1
LC display
2
HOLD
button
3
Illumination button
4
Rotary switch
5
mA/V/Ω socket
6
COM socket
7
Red measuring tip
8
Black measuring tip
9
Fold-out stand
10
Fuse compartment (below stand)
11
Battery compartment
12
10 A socket
13
MODE
button
14
RANGE
button
Rotary switch
15 16
17
18
19
20
21
No.
position
Description
15
OFF
Device is switched off.
16
AC voltage:
200 mV to 600 V
17
DC voltage:
200 mV to 600 V
18
Resistance measurement:
200 Ω to 20 MΩ
Diode test / continuity measurement
19
Direct and alternating current:
up to 200 µA
20
Direct and alternating current:
up to 200 mA
21
Direct and alternating current:
up to 10 A