Trotec BE49 Operating Manual Download Page 11

EN

11

digital multimeter BE49

Continuity test

Warning of electrical voltage

Before carrying out resistance, continuity or diode
measurements, switch off the current of the electric
circuit and discharge all capacitors.

1. Set the rotary switch to position 

 and use the

MODE

 button to select the continuity test (

 indication).

2. Insert the plug of the red measuring tip into the 

V/Ω

 measuring socket and the plug of the black measuring

tip into the 

COM

 measuring socket.

3. Connect the measuring lines to the circuit to be tested.

ð

When the circuit is closed and the resistance is smaller
than 150 Ω, an acoustic signal is emitted.

ð

When the circuit is open, OL is displayed.

Hold function

Press the 

HOLD

 button (2) to freeze the currently measured

value on the display. The 

HOLD

 indication on the display shows

that the hold function is active.
Press the 

HOLD

 button again to exit the hold function and return

to the measuring function. The 

HOLD

 indication disappears.

Switching on the display illumination

Press the illumination button (3) to switch on the background
illumination of the display.
With the display illuminated, press the illumination button (3) to
switch off the background illumination.

Switching the device off

Info

After 15 minutes of inactivity the device switches off
automatically.

Switch the device off by turning the rotary switch to
position 

OFF

.

Maintenance and repair

Battery change

A battery change is required when the battery status indication
displays an empty battery symbol, when incorrect measured
values are displayed or when the device can no longer be
switched on (see chapter Inserting the battery).

Info

In case of a low battery the displayed values may be
inaccurate or incorrect! If so, stop using the measuring
device and exchange the batteries immediately.

Fuse replacement

Caution

Switch the device off and remove the measuring tips
from the measuring sockets before opening the device!
Internal fuses may only ever be replaced with fuses of
the same type, never with one of a higher amperage or
with a provisional solution! Otherwise the
consequences include the risk of accidents, the
destruction of the device and the loss of warranty.

Note

Only replace fuses of the same type!

1. Fold out the stand at the rear of the device.
2. Loosen the screw of the fuse compartment and remove the

fuse compartment cover.

3. Remove the defective fuse.

Summary of Contents for BE49

Page 1: ...TRT BA BE49 TC220328TTRT02 001 EN BE49 EN OPERATING MANUAL DIGITAL MULTIMETER...

Page 2: ...an download the current version of the instructions and the EU declaration of conformity via the following link BE49 https hub trotec com id 46447 Safety Read this manual carefully before starting or...

Page 3: ...ical data To use the device for its intended use only use accessories and spare parts which have been approved by Trotec Foreseeable misuse Do not use the device in potentially explosive atmospheres w...

Page 4: ...ds on the position within a low voltage network in which a device machine is operated The closer this position is to the supply line the higher is the surge voltage to be expected This means that an e...

Page 5: ...lay 2 HOLD button 3 Illumination button 4 Rotary switch 5 mA V socket 6 COM socket 7 Red measuring tip 8 Black measuring tip 9 Fold out stand 10 Fuse compartment below stand 11 Battery compartment 12...

Page 6: ...170 g Dimensions length x width x height 121 mm x 65 mm x 35 mm Automatic switch off after 15 minutes of inactivity Safety This measuring device is designed for indoor use and complies with over volta...

Page 7: ...ries before first use Note Disconnect the measuring tips from the device before opening the battery compartment Note Make sure that the surface of the device is dry and the device is switched off 1 Lo...

Page 8: ...asuring device is not set to the current measuring range If the device indicates an exceedance of the measuring range OL immediately after being connected to the measuring object first switch off the...

Page 9: ...cuit to be checked and connect the measuring device in series with the consumer in this circuit 2 Depending on the expected measuring current turn the rotary switch to position or 3 Use the MODE butto...

Page 10: ...internal resistors of the measuring tips and sockets might lead to a falsified display The resistance value displayed in case of short circuited measuring tips will be put down in writing and later su...

Page 11: ...With the display illuminated press the illumination button 3 to switch off the background illumination Switching the device off Info After 15 minutes of inactivity the device switches off automatical...

Page 12: ...from Directive 2012 19 EU It states that this device must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and el...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: