Trotec BE49 Operating Manual Download Page 2

2

EN

digital multimeter BE49

Table of contents

Notes regarding the instructions  ......................................... 2

Safety ..................................................................................... 2

Information about the device................................................ 4

Transport and storage........................................................... 7

Operation ............................................................................... 7

Maintenance and repair ...................................................... 11

Errors and faults.................................................................. 12

Disposal ............................................................................... 12

Notes regarding the instructions

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
instructions must be observed.

You can download the current version of the instructions and
the EU declaration of conformity via the following link:

BE49

https://hub.trotec.com/?id=46447

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

The device is supplied with warning signs. Prior to initial
start-up, make sure to paste the corresponding warning
signs in your local language, if available, over the ones
present at the rear of the device as described in the
Operation chapter. Otherwise, choose labels in a language
you know.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Protect the device from permanent direct sunlight.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not open the device.

Summary of Contents for BE49

Page 1: ...TRT BA BE49 TC220328TTRT02 001 EN BE49 EN OPERATING MANUAL DIGITAL MULTIMETER...

Page 2: ...an download the current version of the instructions and the EU declaration of conformity via the following link BE49 https hub trotec com id 46447 Safety Read this manual carefully before starting or...

Page 3: ...ical data To use the device for its intended use only use accessories and spare parts which have been approved by Trotec Foreseeable misuse Do not use the device in potentially explosive atmospheres w...

Page 4: ...ds on the position within a low voltage network in which a device machine is operated The closer this position is to the supply line the higher is the surge voltage to be expected This means that an e...

Page 5: ...lay 2 HOLD button 3 Illumination button 4 Rotary switch 5 mA V socket 6 COM socket 7 Red measuring tip 8 Black measuring tip 9 Fold out stand 10 Fuse compartment below stand 11 Battery compartment 12...

Page 6: ...170 g Dimensions length x width x height 121 mm x 65 mm x 35 mm Automatic switch off after 15 minutes of inactivity Safety This measuring device is designed for indoor use and complies with over volta...

Page 7: ...ries before first use Note Disconnect the measuring tips from the device before opening the battery compartment Note Make sure that the surface of the device is dry and the device is switched off 1 Lo...

Page 8: ...asuring device is not set to the current measuring range If the device indicates an exceedance of the measuring range OL immediately after being connected to the measuring object first switch off the...

Page 9: ...cuit to be checked and connect the measuring device in series with the consumer in this circuit 2 Depending on the expected measuring current turn the rotary switch to position or 3 Use the MODE butto...

Page 10: ...internal resistors of the measuring tips and sockets might lead to a falsified display The resistance value displayed in case of short circuited measuring tips will be put down in writing and later su...

Page 11: ...With the display illuminated press the illumination button 3 to switch off the background illumination Switching the device off Info After 15 minutes of inactivity the device switches off automatical...

Page 12: ...from Directive 2012 19 EU It states that this device must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and el...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: